2.2.5
METERS
Seven Fluke 75 multimeters, (equivalent or better)
Or: Four equivalent voltage meters and three equivalent current meters.
The current meters must be capable of measuring 5A+ current
2.3

Equipment Setup

1. Set the power supply #1 for 0V ± 100mVDC, 5.0 ± 0.1A current limit and then turn off supply.
2. Connect the output of power supply #1 in series with a current meter (multimeter) to J1 (VIN, GND).
3. Connect a voltage meter across J1 (VIN, GND).
4. Set the power supply #2 for 0V ± 100mVDC, 1.0 ± 0.1A current limit and then turn off supply.
5. Connect the output of the power supply #2 to J4 and J5 (TS, GND).
6. Connect Load #1 in series with a current meter to J5 (SYS, GND). Turn off Load #1
7. Connect Load #2 in series with a current meter to J5 (BAT, GND). Turn off Load #2.
8. Connect a voltage meter across J5 (BAT, GND).
9. Connect an oscilloscope's probe across J5 (BAT, GND)
10. Connect a voltage meter across J5 (SYS, GND).
11. JP1 (TTC and HI): ON, JP2: ON, JP3 (VPULLUP and VREF): ON, JP4: ON, JP5: OFF.
After the above steps, the test setup for HPA422 is shown in
I
Power
Iin
V
supply #1
Figure 1. Original Test Setup for HPA422 (bq2461x/bq2463x EVM)
SLUU396A – January 2010 – Revised July 2010
bq24610/616/617/30 EVM
HPA422
J1
PH
ACPWR
TP1
ACPWR
PGND
TP2
U1
J3
VCC
ACSET
ISET1
JP4
ISET2
APPLICATION CIRCUIT
GND
VREF
JP3
J2
VEXT
VEXT
HI
GND
L
JP1
JP2
O
TTC
CE
PG
/ACDRV
/BATDRV
bq2461x/bq2463x EVM (HPA422) Multi-Cell Synchronous Switch-Mode Charger
Copyright © 2010, Texas Instruments Incorporated
Figure
1.
TP12
SYS
J5
SYS
BAT
TP9
PGND
VBAT
J4
PG
JP5
STAT1
VREF
TS
/STAT1
/STAT2
Test Summary