Spark modern fires 87N Installation And Operating Instructions Manual

Direct vent gas fireplace

Advertisement

Quick Links

Report # 0 32 1GF003S
WARNING: FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in
serious injury, death, or property damage.
– Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
Ins t allat ion and s er v ic e mus t be per formed b y
a qualified installer, service agency or the g as
supplier.
WARNING: Improper installation, adjustment, alteration,
services or maintenance can cause injury or property
damage. Refer to this manual. For assistance or
additional information consult a qualified installer,
service agency or the gas supplier.
This appliance may be installed in an aftermarket,
permanently
located,
only) or mobile home where not prohibited by local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
conver tible for use with other gases, unless a certified
kit is used.
Version française de ce manuel est disponible à partir du site WEB : www.sparkfires.com
F rench version of this Owner's Manual is available at www.sparkfires.com
SPARK MODERN FIRES
INSTALLATION AND OPERATING INSTRUCTIONS
DIRECT VENT GAS FIREPLACE
MODELS: 87N, 87P
manufactured
home (USA
DUE
TO
HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED OUT
OF TRAFFIC AND AWAY FROM FURNITURE
AND DRAPERIES.
CHILDREN AND ADULTS
ALERTED TO THE HAZARDS
SURFACE TEMPERATURE AND SHOULD
STAY
AWAY
CLOTHING IGNITION.
Y OUNG
CHILDREN
S UPERVISED WHEN THEY ARE IN THE
S AME ROOM AS THE APPLIANCE.
C LOTHING OR
M ATERIAL SHOULD NOT BE PLACED ON
O R NEAR THE APPLIANCE.
K EEP THE ROOM AREA CLEARAND F REE
FROM COMBUSTIBLE MATERIALS, G ASO-
LINE, AND OTHER FLAMMABLE V APORS
.
AND LIQUIDS
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
SHOULD BE
OF HIGH
TO
AVOID
BURNS
SHOULD
OTHER FLAMMABLE
OR
BE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 87N and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Spark modern fires 87N

  • Page 1 ™ INSTALLATION AND OPERATING INSTRUCTIONS DIRECT VENT GAS FIREPLACE Report # 0 32 1GF003S MODELS: 87N, 87P WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    CONTENTS Important Safety Information ......3 Electrical Installation........28 Electrical Wiring ........28 Product Features..........5 Wall Switch ..........28 Code Approval ..........5 Glass Removal ..........29 Pre-Installation Information......6 Final Installation........... 30 ......Installing Above 2000 Feet ......6 Placement ..
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION INSTALLER OWNER Please leave these instructions with the owner. Please retain these instructions for future reference. WARNING • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. • Any change to this fireplace or its controls can be dangerous. •...
  • Page 4 IMPORTANT SAFETY INFORMATION Continued from page 3 IMPORTANT: 12. Do not use this fireplace to cook food or burn paper or PLEASE READ THE FOLLOWING CAREFULLY other objects. It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or 13.
  • Page 5: Product Features

    PRODUCT FEATURES CODE APPROVAL FIREPLACE CONTROLS PRODUCT SPECIFICATIONS (see Figure 1) • This appliance has been certified 1 - Hi/Lo Knob for use with either natural or 2 - Off/Pilot/On Knob propane gas. See appropriate data 3 - Remote Control Receiver (optional) plates.
  • Page 6: Pre-Installation Information

    PRE-INSTALLATION INFORMATION INSTALLING ABOVE 2000 FEET • In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elevations (at the factory). • In Canada, these appliances are certified for altitudes of 0 – 4,500 ft. ORIFICE SIZES, PRESSURES AND BTUs NATURAL GAS PROPANE GAS...
  • Page 7: Fireplace Framing

    5. PLEASE NOTE: Natural stone products may react to heat by discoloring or cracking. Spark Modern Fires is not resposible for any damages due to covering materials used. If tiles are to be applied covering the fireplace face, a layer of cement board must be used as a substrate.
  • Page 8: Fireplace Dimensions

    PRE-INSTALLATION INFORMATION MODEL DV 8 7 DIMENSIONS TOP VIEW RIGHT SIDE VIEW WITH 30 DEGREE ELBOW 16.5" 45" VENT VENT ELBOW ELBOW 36.0" 22.5" 32" 24.9" 10" GAS AND ELECTRICAL 22.5" ACCESS HOLES (BOTH SIDES) FRONT VIEW RIGHT SIDE VIEW WITH 60 DEGREE ELBOW 45"...
  • Page 9: Fireplace Location

    PRE-INSTALLATION INFORMATION FIREPLACE LOCATION Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspections.
  • Page 10: Securing Fireplace To Floor Or Framing

    SECURING FIREPLACE TO FLOOR OR FRAMING The fireplace must be secured to the floor and/or to framing studs as shown in Figure 5. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side brackets are adjustable from 1/2"...
  • Page 11: Clearances

    CLEARANCES CLEARANCES TO COMBUSTIBLES WARNING Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
  • Page 12: Installation Information

    The following actions will void the warranty on your venting system: • Installation of any damaged venting component. • Unauthorized modification of the venting system. • Installation of any component part not manufactured or approved by Spark Modern Fires. • Installation other than permitted by these instructions.
  • Page 13: Vent Installation

    VENT INSTALLATION WARNING This fireplace must be vented to the outside. The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance must use a separate vent system. Do not use common vent systems. WARNING A Minimum of 3"...
  • Page 14: Installation Planning

    VENT INSTALLATION INSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness.
  • Page 15 VENT INSTALLATION FOR HORIZONTAL TERMINATION Inside Corner Detail � � � � � � � � � � � � � ����� � � ������ ������ ����� � ��� ������ � � �������� � � � � � � � �...
  • Page 16 VENT INSTALLATION TERMINATION CLEARANCES FOR BUILDINGS WITH COMBUSTIBLE AND NONCOMBUSTIBLE EXTERIORS � � � ���� ������� � � � � � ���� ������� ������ ������ ������� ������ � � ������� ����� �� ��� �������� � ��� ������ �������� � � ������� ����� ��� ���� ���� �� �...
  • Page 17: Rear Wall Vent Installation

    VENTING INSTALLATION REAR WALL VENT INSTALLATION When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance • The maximum horizontal distance between the rear of the appliance and the outside of termination is 20" (508 m). See Figure 11.
  • Page 18 VENT INSTALLATION REAR WALL VENT INSTALLATION (continued) 4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the center of hole on the exterior wall with the word “UP” on the vent cap facing up.
  • Page 19: Horizontal Termination Configuration

    VENT INSTALLATION HORIZONTAL TERMINATION CONFIGURATIONS — RIGID VENTING Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to. The Vent Graph, showing the relationship between vertical and horizontal side wall venting, will help to determine the various dimensions allowable.
  • Page 20 VENT INSTALLATION 90° HORIZONTAL TERMINATION CONFIGURATION — RIGID VENTING (Continued) • If a 90° elbow is used in the horizontal vent run (level height maintained) the horizontal vent length is reduced by 36" (914 mm) (Fig. 21 A and B) This does not apply if the 90° elbows are used to increase or redirect a vertical rise.
  • Page 21: Below Grade Installation

    VENT INSTALLATION BELOW GRADE INSTALLATIONS — RIGID VENTING When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178mm) below grade level. The 7" (178mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall.
  • Page 22: Vertical Through-The-Roof Installation

    VENT INSTALLATION VERTICAL THROUGH-THE-ROOF APPLICATIONS — RIGID VENTING ONLY This Gas Fireplace has been approved for, V ertical installations up to 40' (12m) in height. Up to a 10' (3m) horizontal vent run can be installed within the vent system •...
  • Page 23: Installation For Vertical Termination

    VENT INSTALLATION INSTALLATION FOR VERTICAL TERMINATION 1. Determine the route your vertical venting will take. If ceiling joist, Roof roof rafters or other framing will obstruct the venting system, consider Flashing an offset. See Figure 27 to avoid cutting load bearing members. NOTE: Pay special attention to these installation instructions for required clearances (air space) to combustibles when passing Wall Strap...
  • Page 24: Cathedral Ceiling Installation

    VENT INSTALLATION 4. Connect a section of pipe and extend up through the hole. NOTE: If an offset is needed to avoid obstructions, you must support the vent pipe every three (3) feet. Use wall straps for this purpose. See Figure 25, page 22. Whenever possible, use 45° elbows instead of 90° elbows. The 45° elbow offers less restriction to the flow of the flue gases and intake air.
  • Page 25: Fireplace Installation

    FIREPLACE INSTALLATION CHECK GAS TYPE Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit. INSTALLING GAS PIPING TO FIREPLACE / BURNER SYSTEM LOCATION WARNING A qualified installer or service person must...
  • Page 26 FIREPLACE INSTALLATION CAUTION WARNING Only persons licensed to work with gas piping A manual shutoff valve must be installed upstream may make the necessary gas connections to of the appliance. Union tee and plugged " this appliance. NPT pressure tapping point should be installed upstream of the appliance.
  • Page 27: Checking Gas Pressure

    CHECKING GAS PRESSURE Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance. Contact your dealer immediately. Control knob 2.
  • Page 28: Electrical Installation

    ELECTRICAL INSTALLATION ELECTRICAL WIRING This fireplace will work without any electrical supply. Electricity is only needed to operate blower. NOTE: If installed in mobile home, fireplace must be bolted securely to floor. WARNING Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service.
  • Page 29: Glass Removal

    GLASS REMOVAL GLASS FRAME REMOVAL GLASS REMOVAL 1. Remove the front air panel using a screwdriver to lift from center if necessary. 2. Remove the left and right side panels by lifting up and moving to the center. . Loosen and remove the three nuts at the top of the glass door frame. .
  • Page 30: Final Installation

    FINAL INSTALLA TION MEDIA TRAY PLACEMENT (OPTIONAL) 1. Place media tray (see figure 37) on the support brackets as shown on figure 38. Fill the tray with media supplied. Do not place media on burner or block air flow between burner and tray (see figure 39). Figure 37 - Media tray Figure 38 - Placing media tray Figure 39 - Filling the tray with media...
  • Page 31: Safety Screen Installation

    SAFETY SCREEN INSTALLATION WARNING: A barrier (safety screen) designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shell be installed for the protection of children and other at-risk individuals. IMPORTANT: Safety Screen must be in place when the fireplace is in operation. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer's barrier for this appliance.
  • Page 32 SAFETY SCREEN INSTALLATION (continued) STEP 5: Insert the right side panel into the STEP 6: Match up the tabs in the panel with the slots in the face and slide downward. Make opening angling in at the top. sure the side panel is secured properly. Repeat Steps 5 and 6 for the Left Side Panel.
  • Page 33: Operating Instructions

    OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit with built-in battery ignitor while following these instructions exactly.
  • Page 34: Lighting Pilot

    OPERATING INSTRUCTIONS LIGHTING PILOT FOR THE FIRST TIME APPROVED LEAK TESTING METHOD You may check for gas leaks with the following methods only: • Soap and water solution WARNING • An approved leak testing spray If using a soap and water solution to test for leaks, DO NOT spray solution onto •...
  • Page 35: Lighting Burner

    OPERATING INSTRUCTIONS LIGHTING BURNER MAIN BURNER SWITCH The “ON/OFF” switch for the main burner can be found either in the fireplace or on the wall depending on installation. This switch allows you to turn on and to turn off the main burner without using the gas valve knob.
  • Page 36: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. BURNER, PILOT AND CONTROL COMPARTMENT Keep the control compartment and burner areas clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times.
  • Page 37: Vent System

    CLEANING AND MAINTENANCE VENT SYSTEM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function.
  • Page 38: Replacement Par Ts

    ILLUSTRATED PARTS LIST RIGID VENT COMPONENTS (not supplied with fireplace) � � � Simpson Duravent Direct Vent Pro or Item Qty/Box Description Spark Modern Part # 46DVA-E30 — 30° Starter Elbow for Vertical from Firebox 46DVA-E60 — 60° Starter Elbow for Horizontal from Firebox 46DVA-HC Simpson Horizontal High Wind Horizontal Termination Cap 46DVA-VCH...
  • Page 39: Firebox Components

    ILLUSTRATED PARTS LISTS CONTROL COMPARTMENT BURNER COMPARTMENT FIREBOX COMPONENTS ACCESS AND MEDIA COMPONENTS...
  • Page 40 ILLUSTRATED PARTS LISTS PARTS LIST This list contains replaceable parts used in your fireplace. All replacement parts should be ordered from your installer or from Spark Modern Fires at 1-866-938-3846 or on-line at www. sparkfires .com PART NUMBER DESCRIPTION C100012...
  • Page 41: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE ACTION 1. Spark ignitor will not A. Wire disconnected. A. Open door and check to make sure wire is connected to ignitor. light pilot after repeated B. Check for spark at electrode and pilot. If no spark and electrode triggering of piezo.
  • Page 42 NOTES...
  • Page 43 The installer should keep a duplicate of this form for their records. Accurate com- pletion of this form is required for warranty coverage and for any technical support by Spark Modern Fires. Date Purchased:...
  • Page 44: Warranty

    Spark Modern Fires will also pay for reasonable labor cost incurred in replacing or repairing such components for a period of two years from date of installation. Any products presented for warranty repair must be accompanied by a dated proof of purchase.

This manual is also suitable for: