Location - Scotsman F1322L Installation And User Manual

Remote low side modular flaked and nugget ice machines
Table of Contents

Advertisement

N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual

Location:

While the machine will operate satisfactorily within the
air and water temperature limits, it will operate more
efficiently when those temperatures are nearer the
lower limits. Avoid locations that are hot, dusty, greasy
or confined.
Options
The standard machine will make ice until ice fills
the bin and blocks an infrared light beam inside the
bottom of the machine. A field installed kit is available
to adjust the ice level lower. That kit number is KVS.
The standard controller has excellent diagnostic
capabilities and communicates to the user through the
AutoAlert light panel, seen through the front panel.
There is a field installed kit that can log data and
provide additional information when the front panel is
removed. That kit number is KSBU. A similar kit adds
network connectivity, and its number is KSB-NU.
Bin compatibility
All models are the same width: 22 inches. All models
are the same depth: 24 inches.
Bin & adapter list:
• B322S – no adapter needed
• B330P – Use KBT27
• B530P – Use KBT27
• B530S – Use KBT27
• B842S – Use KBT39
• B948S - Use KBT38 for a single unit
• B948S – Use KBT38-2X for two units side by side
BH1100, BH1300 and BH1600 upright bins include
filler panels to accommodate a single 22 inch wide
flake or nugget ice machine. No adapter is needed.
Dispenser compatibility
Only nugget ice models may be used with ice
dispensers. Flaked ice is not dispensable.
• ID150 – use KBT42 and KDIL-PN-150; includes
KVS, KNUGDIV and R629088514
• ID200 – use KBT43 and KNUGDIV and KVS
• ID250 – use KBT43 and KNUGDIV and KVS
See sales literature for other brand model ice and
beverage dispenser applications.
Other Bins & Applications:
Note the drop zone and ultrasonic sensor locations in
the illustrations on the next page.
Line Set
NRTE45 is a non-precharged tubing kit that contains
a 45 foot 3/8" liquid line and a 45 foot 5/8" suction
line. Tubes are supplied nitrogen charged and
capped.
Scotsman ice systems are designed and
manufactured with the highest regard for safety and
performance.
Scotsman assumes no liability of responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the use
of any part and/or other components not specifically
approved by Scotsman.
Scotsman reserves the right to make design changes
and/or improvements at any time. Specifications and
design are subject to change without notice.
October 2014
Page 4

Advertisement

Table of Contents
loading

This manual is also suitable for:

F1222lProdigy plus d seriesN0922lN1322l

Table of Contents