Typical Inlet Pipe Diameters
Use 3/8" black iron pipe or greater. Installa-
tion must include an equipment shutoff valve,
union, and plugged 1/8" NPT tap. Locate
NPT tap within reach for test gauge hook up.
NPT tap must be upstream from heater (see
Figure 12).
IMPORTANT: Install an equipment shutoff
valve in an accessible location. The equip-
ment shutoff valve is for turning on or shutting
off the gas to the appliance.
For propane/LP installations, apply pipe
joint sealant lightly to male threads. This will
prevent excess sealant from going into pipe.
Excess sealant in pipe could result in clogged
heater valves.
Ground
Joint Union
Tee Joint
Reducer
Bushing to
1/8" NPT
1/8" NPT
Plug Tap
Tee Joint
Pipe Nipple
Gap
Figure 12 - Gas Connection
* Purchase the optional CSA design-certified equipment
shutoff valve from your dealer (see Accessories, page 25).
Gas Regulator
Inlet Connector
Figure 14 - Gas Regulator Location and Gas Line Access into Stove Cabinet
14
INSTALLATION
The installer must supply an external regula-
tor. The external regulator will reduce incom-
ing gas pressure. You must reduce incoming
gas pressure to between 11" and 14" of water.
If you do not reduce incoming gas pressure,
heater regulator damage could occur. Install
external regulator with the vent pointing down
as shown in Figure 13. Pointing the vent down
protects it from freezing rain or sleet.
Install sediment trap in supply line as shown
in Figure 12. Place sediment trap where it is
within reach for cleaning. Place sediment trap
where trapped matter is not likely to freeze.
A sediment trap traps moisture and contami-
nants. This keeps them from going into heater
controls. If sediment trap is not installed or is
installed wrong, heater may not run properly.
3/8" NPT Pipe Nipple
Equipment
Shutoff Valve
Natural Gas
From Gas Meter
(5" W.C.** to
9" W.C. Pressure)
Propane/LP
From External
Regulator
(11" W.C.**
to 14" W.C.
3" Minimum
Pressure)
www.sureheat.com
Propane/LP
Supply Tank
Figure 13 - External Regulator
with Vent Pointing Down
External
Regulator with
Vent Pointing
Down
200252-01A

Advertisement

Chapters

Table of Contents
loading

Table of Contents