Specifications - Greenlee TG-100 Instruction Manual

Temperature guns
Table of Contents

Advertisement

Available languages

Available languages

Specifications

Display: 3-1/2–digit LCD (199.9 or 1999 maximum display)
Response Time: 500 milliseconds., 95% response
Target Temperature Range:
TG-100: –32 C to 400 C (–25 F to 750 F)
TG-200: –32 C to 500 C (–25 F to 932 F)
TG-300: –32 C to 540 C (–25 F to 1000 F)
Spectral Response:
TG-100 and TG-200: 7 to 18 m
TG-300: 8 to 14 m
Emissivity:
TG-100: Preset at 0.95
TG-200 and TG-300: 0.3 to 1.0 digitally adjustable
Ambient/Operating Temperature Range: 0 C to 50 C (32 F to 122 F)*
Relative Humidity: 10% to 95% (noncondensing)
Storage Conditions: –25 C to 70 C (–13 F to 158 F)*. Remove battery.
Battery: 9-Volt (NEDA 1604, JIS 006P or IEC 6F22)
* For improved accuracy, allow unit 30 minutes to adjust to large change in temperature.