Wiring; Maintenance - Empire Comfort Systems VFP20IN30L10-1 Installation Instructions And Owner's Manual

Unvented gas fireplace models
Table of Contents

Advertisement

Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
Millivolt thermopile is self powered, gas valve does
not require 110 volts. Maximum length of 20 feet of
16 AWG to conductor wires is to be used with all
optional switches.
Use the two leads (Red and Green) to attach optional
components.
Check 750 Millivolt System Operation
Millivolt system and all individual components may be
checked with a millivolt meter 0-1000 MV range.
Remote Receiver
Use the following steps to place the remote receiver
adjacent to the gas valve.
Attention: The remote receiver bracket is not used
in this installation.
1. The remote receiver can not be placed behind
the gas valve and burner assembly.
2.
When facing the appliance, the remote receiver
must be placed to the right of the gas valve.
Install remote control receiver behind bottom
louver.
Refer to remote control installation and operating
instructions for more details on remote control.
Keep the control compartment, logs and burner area surrounding the
logs clean by vacuuming or brushing area at least twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN
COOL.
Always turn off gas to the pilot before cleaning. For relighting, refer
to lighting instructions located on the rating plate of the log set.
29829-19-1017

WIRING

WIRING DIAGRAM
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
(OPTIONAL) WALL SWITCH
INTERRUPTEUR MURAL
(FACULTATIVE)
THERMOPILE
PILOT
VEILLEUSE
THERMOCOUPLE
(LPG)
THERMOCOUPLE
(NATURAL)

MAINTENANCE

Never obstruct the flow of the combustion and ventilation air. Keep
the front of the fireplace clear of all obstacles and materials.
Leave at least 36" clearance from the front of the fireplace.
Screen should be closed during operation.
REMOTE CONTROL RECEIVER/
THERMOSTAT/ CONTROLE E
DISTANCE DU RECEPTEUR
H
N
GAS VALVE
VALVE DE GAZ
REMOTE/OFF/ON SWITCH
A DISTANCE/OUVERT/
FERME INTERRUPTEUR
(OPTIONAL) REMOTE CONTROL RECEIVER
(FACULTATIVE) CONTROLE E DISTANCE
DU RECEPTEUR
REMOTE/OFF/ON SWITCH
A DISTANCE/FERME/OUVERT
INTERRUPTEUR
REMOTE
OFF
IF ANY OF THE ORIGINAL WIRE
ON
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150°C
WIRE OR ITS EQUIVALENT.
SI UN DES FILS ELECTRIQUES
ORIGINAUX, VENANT DU FABRICANT
AVEC CETTE UNITE, DOIT ETRE
REMPLACE, VOUS DEVEZ LE
GAS VALVE
REMPLACER AVEC UN FIL
ELECTRIQUE DE NUMERO 18,
150
°
C DU L'EQUIVALENT.
Figure 37
Page 35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents