Download Print this page
DuraHeat DH2304S Manual
Hide thumbs Also See for DH2304S:

Advertisement

Available languages

Available languages

Quick Links

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
CHECKING THE IGNITION SYSTEM
If the automatic ignition system fails to operate properly,
perform the following checks:
BATTERIES -2 "C" cell batteries are located at the rear of the heater.
Replace with new batteries.
IGNITER PLUG - If the automatic ignition system still doesn't work
after replacing the batteries, check the igniter plug. If the glow coil
filament is broken, bent, or doesn't glow when engaged via the ignition lever, it must be replaced.
CAUTION: Be sure igniter plug is Type "B", 2.5V DC, 1A only.
To replace the igniter plug (Fig.15);
Remove the batteries.
Remove the 2 cabinet screws and lift off the cabinet and grill assembly.
Pull the ignition lever to raise the igniter plug.
Push the igniter plug in and turn in a clockwise direction to remove.
Install a new igniter plug (Type "B", 2.5V DC, 1A only) by pushing it in and turning it in a
counter-clockwise direction.
Reassemble the heater and replace the batteries.
TEST IGNITION
ADJUSTING THE WICK
After lighting the heater, it is important to check the heater flame within the first 5-7 minutes of operation.
During the first 5 minutes after ignition, the burner chamber warms up and flames will become visible at the top
of burner. These flames will gradually build up. After 5-7 minutes of operation, you should use the wick
adjuster knob to obtain the proper flame height. The proper flame height is a flame of no more than 1/2" at the
top of the burner, with an even distribution of flame around the flame spreader disk which is positioned in the
center of the top portion of the burner. See pictures below for reference.
As you continue to operate the heater, the temperature of the heater and the temperature of the room will
continue to change. As the heater warms up, the kerosene in the tank will vaporize faster, and this could
require adjusting the wick adjuster down in order to maintain the desired 1/2" flame height. Therefore, it is
necessary to continue to monitor the flame height, and to make adjustments using the wick adjuster knob to
keep the proper flame height. It is recommended that the heater be checked every 30 minutes in order to keep
the proper adjustment because periodic adjustment is required.
CORRECT FLAME
Proper combustion
IMPORTANT NOTE : NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING.
Always make sure to turn the heater off and inspect it to insure that it is completely
extinguished prior to going to bed.
Using the wick adjuster knob, raise the wick to its maximum height.
Pull the ignition lever.
The igniter plug should be within 1~2mm of the wick when the ignition lever is
fully engaged.
Fig.16
FLAME TOO HIGH
Can Produce smoke
and soot
12
Igniter
Fig.15
FLAME TOO LOW
Can produce odor
and carbon monoxide

Advertisement

loading
Need help?

Need help?

Do you have a question about the DH2304S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DuraHeat DH2304S

  • Page 1 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! CHECKING THE IGNITION SYSTEM If the automatic ignition system fails to operate properly, perform the following checks: Igniter BATTERIES -2 "C" cell batteries are located at the rear of the heater. Replace with new batteries. Fig.15 IGNITER PLUG - If the automatic ignition system still doesn't work after replacing the batteries, check the igniter plug.
  • Page 2 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! NOTE : During start-up, small adjustments to the flame can be performed by using the burner knob on the front of the burner and MOVING THE BURNER FROM SIDE TO SIDE until the flame at the top of burner is as even as possible.
  • Page 3: Wick Replacement

    http://worldmkting.com/wick-installation-instructions NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! WICK ASSEMBLY- Check at least once a month!! The burner assembly sits on top of the wick guide. Over time, tar deposits can accumulate on the wick guide, and this can prevent the burner assembly from seating properly.
  • Page 4 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! . Remove the four wing nuts . Replace the wick adjustment knob temporarily. which hold the wick assembly Turn the knob CLOCKWISE to raise the wick. to the heater and carefully lift the wick assembly from the heater.
  • Page 5 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! .Turn the wick assembly upside down to replace the wick cover. . Align the tabs on the wick cover with the four screw holes on the bottom of the assembly, as shown, and snap it into place.
  • Page 6: Extinguishing The Heater

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! EXTINGUISHING THE HEATER To extinguish the heater, push down on the manual shut-off knob (Fig.18) with one hand while holding the wick adjuster knob in the other hand. You will feel the pressure of spring action attempting to turn the wick adjuster knob in a counter- clockwise direction in your hand.
  • Page 7: Long Term Storage Of Your Heater

    NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! TESTING THE SAFETY SHUT-OFF DEVICE : At least once a week during the heating season, it is important to test the safety shut-off device to be sure that it is operating properly. WITH THE HEATER TURNED OFF, raise the wick using the wick adjuster knob to the fully raised position.
  • Page 8 CONTROLAR EL SISTEMA DE IGNICION Si la ignición automática no funciona correctamente, realice las pruebas siguientes: - PILAS - 2 "C" las pilas se localizan atrás en el calentador. Reemplace con pilas nuevas. - EL TAPÓN DEL MECHERO - Si el sistema de la ignición automático todavía no funciona después de reemplazar las pilas, mire al tapón del mechero.
  • Page 9 NOTA: Cuando primero encienda al calentador, pequeños ajustes a la llama pueden ser realizados por usar el bulto del quemador en el frente del quemador y MOVER EL QUEMADOR DE UN LADO AL OTRO hasta que la llama encima del quemador está igualado tanto como posible. No TOQUE EL BULTO del QUEMADOR UNA VEZ QUE EL CALENTADOR ha ALCANZADO TEMPERTURA NORMAL EN QUE FUNCIONA Y LA LLAMA se ha ESTABILIZADO.
  • Page 10 COMUNES”, en la página 14, que señala condiciones en que la mecha debe reemplazarse. CUATELA: Use SOLO una Mecha del Reemplazo autentica. El número es: Kero-World 32225, DuraHeat DH-145 y Pick-A-Wick PW-72. No intente sustituir cualquier otro tipo de mecanismo o una mecha diseñada para otra marca o modelo de calentador. Usted podría dañar el calentador y podría crear un riesgo de fuego potencial.
  • Page 11 Quite las cuatro tuercas de Vuelva a poner el bulto del ajustador de mecha mariposa que mantiene el temporalmente. montaje de la mecha junto al Gire el bulto EN EL SENTIDO DE LAS AGUJAS calentador y cuidadosamente DEL RELOJ para subir la mecha. levante el montaje de la mecha del calentador.
  • Page 12 . Ponga el montaje de la mecha al revés para re poner la tapa de la mecha. . Alinee las etiquetas en de la tapa de la mecha con los cuatro agujeros de tornillo en el fondo del montaje, como se muestra, presionela en su lugar.
  • Page 13 EXTINGUIR EL CALENTADOR Para extinguir el calentador, apriete hacia abajo en el bulto del interruptor manual (Ilu. 18) con una mano mientras detengas el bulto de ajustador de mecha en la otra mano. Usted sentirá la presión en su mano de la acción del resorte que intentará...
  • Page 14 PROBAR EL INTERRUPTOR AUTOMÁTICO DE SEGURIDAD: por lo menos una vez a la semana durante la estación de usar el calentador, es importante probar el interruptor automático de seguridad para estar seguro que está funcionando correctamente. CON EL CALENTADOR APAGADO, suba la mecha que con el bulto del ajustador de mecha a la posición totalmente subida.