Liquid Gas Connection (Lpg); Conversion To A Different Gas Type; Converting To A Different Gas Type; Functional Parts For The Gas Conversion - Bosch HGD745256N Instructions For Connecting

Gas and gas conversion
Hide thumbs Also See for HGD745256N:
Table of Contents

Advertisement

Available languages

Available languages

Liquid gas connection (LPG)

Caution!
Follow country-specific guidelines.
If liquid gas (LPG) is used, the gas connection is established
via a gas hose or a fixed connection.
If a gas hose is used, pay attention to the following measures:
Use a safety hose or plastic hose (8 or 10 mm diameter).
Secure it to the gas connection with a connecting device (e.g.
a hose clamp).
The hose must be short and fully leakproof. The hose must
not be longer than 1.5 m. Pay attention to current guidelines.
The gas hose must be replaced annually.
Place the new seal on the connecting piece. Make sure that
1.
the seal is correctly seated.
Attach the connecting piece (with a size 24 key) to the end of
2.
the gas connection (with a size 22 key).

Conversion to a different gas type

Converting to a different gas type

The gas connection must be replaced.
The burner nozzles must be replaced.
Depending on the factory gas setting, the bypass screws in
the burner valves must either be replaced, or screwed in fully.
If present, the oven and grill nozzles must also be replaced.
Numbers are printed on the nozzles indicating their diameter.
Further information about the gas types suitable for the
appliance, as well as the corresponding gas nozzles, can be
found in the section entitled "Technical properties - gas".
After the conversion
After the appliance has been converted to a different gas
type, you must perform a leak test. See the section entitled
"Leak test".
After the appliance has been converted to a different gas
type, the correct flame formation must be tested. See the
section entitled "Correct flame formation".
Enter the newly-set type of gas and gas pressure in the table.
See the section entitled "Measures to be observed".
Caution!
After the appliance has been converted to a different gas type,
the labels giving information on the gas type and showing a
star must be affixed at the appropriate point on the rating plate
MAKE SURE THAT YOU DO THIS.
4
Insert the safety hose and tighten using a screw coupling or
3.
hose clamp.
To perform a leak test, see the section entitled "Leak test".
4.
Open the gas supply.
Note: A torque spanner must be used when the gas is
connected.

Functional parts for the gas conversion

The functional parts that are required for the gas conversion in
accordance with the instructions are displayed below.
You will find the correct nozzle diameters in the table in the
section entitled "Technical properties - gas".
Always use new seals.
The gas connecting piece to be used may vary depending on
the gas type and country-specific regulations.
(*) These functional parts must be used when the gas is
connected.
Bypass screw
Burner nozzle
(*) Seal

Advertisement

Chapters

Table of Contents
loading

Table of Contents