Midea CTBU-09HWFN1-M Service Manual page 95

Light commercial mono 3d air conditioner
Table of Contents

Advertisement

22
1# Indoor unit capacity demand code
23
2# Indoor unit capacity demand code
24
3# Indoor unit capacity demand code
25
Room temp. T1 of 1# indoor unit
26
Room temp. T1 of 2# indoor unit
27
Average room temp. T1
28
Reason of stop
29
Evaporator pipe temp. T2B of 1# indoor unit
30
Evaporator pipe temp. T2B of 2# indoor unit
connected, the digital display tube will show: "――"
Actual data*HP*10
If capacity demand code is higher than 99, the digital display
tube will show single digit and tens digit. (For example, the
digital display tube show "5.0",it means the capacity demand
is 15. the digital display tube show "60",it means the
capacity demand is 6.0). If the indoor unit is not connected,
the digital display tube will show: "――"
If the temp. is lower than 0 degree, the digital display tube
will show "0".If the temp. is higher than 70 degree, the digital
display tube will show "70". If the indoor unit is not
connected, the digital display tube will show: "――"
If the temp. is lower than 0 degree, the digital display tube
will show "0".If the temp. is higher than 70 degree, the digital
display tube will show "70". If the indoor unit is not
connected, the digital display tube will show: "――"
92