4) Remove the chute assembly from the icemaker.
5) Remove the chute packing at the bottom of the chute. Remove the 3 ties and the chute
insulation.
6) Soak the spout, evaporator packing (F-450), rubber O-ring and nylon ring (FD-650
and larger), spout-to-chute packing, spout-to-chute bracket, and chute in the sanitizing
solution for 10 minutes then wipe them down.
7) Rinse the parts thoroughly with clean water.
8) Replace all parts in their correct positions.
9) Move the control switch to the "ICE" position, then move the power switch to the "ON"
position. Replace the panels in their correct positions, then turn on the power supply.
Make ice using the solution until the icemaker stops making ice.
10) Turn off the power supply, then remove the front panel. Move the control switch to the
"DRAIN" position, then replace the front panel in its correct position.
11) Turn on the power supply and allow the water system to drain for 5 minutes.
12) Turn off the power supply.
5. Sanitizing Procedure - Final
1) Mix a new batch of the sanitizing solution.
2) Make sure the power supply is off and the icemaker water supply line shut-off valve
is closed. Remove the front and top panels, then move the power switch to the "OFF"
position.
3) Remove the upper and lower straps connecting the spout to the chute assembly, then
remove the spout.
4) Pour the sanitizing solution over the extruding head until the evaporator assembly and
the reservoir are full and the solution starts to run through the overflow hose on the
reservoir.
5) Replace the spout and straps in their correct positions.
6) Allow the icemaker to sit for 10 minutes before operation.
7) Move the control switch to the "ICE" position, then move the power switch to the "ON"
position. Replace the panels in their correct positions, then turn on the power supply.
Make ice using the solution until the icemaker stops making ice.
8) Turn off the power supply, then remove the front panel. Move the control switch to the
"DRAIN" position, then replace the front panel in its correct position.
9) Turn on the power supply and allow the water system to drain for 5 minutes.
10) Turn off the power supply, then remove the front panel. Move the control switch to the
"ICE" position, then replace the front panel in its correct position.
11) Open the icemaker water supply line shut-off valve, then turn on the power supply to
supply water to the reservoir.
12) After the gear motor starts, turn off the power supply. Remove the front panel, then move
the control switch to the "DRAIN" position. Replace the front panel in its correct position.