Volt101A
Range
Resolution
*See Table for Details
Accuracy
Memory
Wrap Around
Reading Rate
4 readings every second (4Hz) to 1 every 24 hours
LED Indicator
Channels
Required Interface Package
Baud Rate
Typical Battery Life
Operating Environment
Material
Dimensions
1.4 in x 2.5 in x 0.6 in (36 mm x 64 mm x 16 mm)
Weight
Approvals
*Volt101A Range, Resolution and Calibrated Accuracy
Range
Measurement Range (VDC)
Accuracy
Resolution (mV)
Overload Protection
Battery Warning
WARNING: FIRE, EXPLOSION, AND SEVERE BURN HAZARD. DO NOT SHORT CIRCUIT, CHARGE,
FORCE OVER DISCHARGE, DISASSEMBLE, CRUSH, PENETRATE OR INCINERATE. BATTERY MAY
LEAK OR EXPLODE IF HEATED ABOVE 80 °C (176 °F).
Find Quality Products Online at:
Volt101A-160mV
±160 mVDC
5 μV
±0.01 %FSR
1,000,000 readings
330,000 in enhanced start/stop mode
Yes
Red & Green
1
IFC200
115,200
10 years at a 15 minute reading rate
-40 °C to +80 °C (-40 °F to +176 °F),
0 to 95%RH non–condensing
ABS plastic
0.9 oz (24 g)
CE
2.5 V
15 V
30 V
-3 to +3 V
-8 to +24 V
-8 to +32 V
+0.05%FSR
0.1 mV
0.5 mV
1.0 mV
+50 V, indefinitely
DOC-1210035-00 REV 7 2014.11.26
www.
Product User Guide
Volt101A-2.5V
2.5VDC Voltage Data Logger
Volt101A-15V
15VDC Voltage Data Logger
Volt101A-30V
30VDC Voltage Data Logger
GlobalTestSupply
.com
Volt101A-160mV
+160mVDC Differential Voltage
Data Logger
Red 485
Dark Blue Pantone 289
Light Blue 58% of Pantone 289
sales@GlobalTestSupply.com
Volt101A &
Volt101A-160

Advertisement

loading

Summary of Contents for MadgeTech Volt101A-2.5V

  • Page 1 Dimensions 1.4 in x 2.5 in x 0.6 in (36 mm x 64 mm x 16 mm) Weight 0.9 oz (24 g) Approvals Volt101A-2.5V Volt101A-160mV 2.5VDC Voltage Data Logger +160mVDC Differential Voltage *Volt101A Range, Resolution and Calibrated Accuracy Data Logger Range 2.5 V...
  • Page 2 - Downloading will offload and save all the recorded data to the PC. temperature, CO2, flow rate and more. Please refer to the application note “Engineering Units”, found on the MadgeTech website, for information on how to manage Engineering Device Maintenance Units.

This manual is also suitable for:

Volt101a-160Volt101aVolt101a-15vVolt101a-30vVolt101a-160mv