Firmware Update; Factory Reset; Functions Settings; Reversing Channels - Conrad Electronic RC Logger R8 Operating Instructions Manual

Digital proportional radio control system
Table of Contents

Advertisement

11.4.11 Firmware update

Navigate and set:
System > OK > Firmware update > OK > UP/DOWN > OK
Latest firmware releases are available from www.rclogger.com. Check regularly.
A Windows
computer with USB interface is required for updating the firmware.
®
1. Turn the »Transmitter off.
2. Disconnect the »Receiver from the power supply.
3. Connect the trainer plug of the USB cable (supplied) to the trainer port TRAINER and
the USB A-type plug to a free USB socket (USB2.0 or USB3.0) on the computer.
4. Turn the »Transmitter on.
5. Navigate to the firmware update section in the »Transmitter's menu and start the
update procedure. Confirm the confirmation prompt if you are ready to continue or else
cancel the update procedure.
6. Follow the computer's instructions to complete the update.
7. After the firmware has been updated, disconnect the USB cable.
8. Turn the »Transmitter off and on again.
9. The »Transmitter is ready for use.

11.4.12 Factory reset

Navigate and set:
System > OK > Factory reset > OK > OK > UP/DOWN > OK
This function will reset all »Transmitter settings to their factory default values.
Important! Note that all system and modes settings will be lost and cannot be recovered
once the reset process is in progress.

11.5 Functions settings

In the functions settings menu you adjust the settings for each model. Before you start to
make adjustments, select a model in the System Settings (see '11.4 System settings' on
page 13 '11.4 System settings' on page 13).
16 | Transmitter

11.5.1 Reversing channels

This function lets you reverse channels (see
needs and preferences: Ch = Channel, Nor = Normal (Default), Rev = Reversed
Navigate and set:
Functions > OK > Reverse > OK > UP/DOWN > OK > ... > OK (long)
Use the key OK for navigating between the channels (CH1 – CH8).
Reverse
1
2
3
4
Ch
Nor
Rev

11.5.2 End points

This function lets you set the travel of each channel (see
smaller and increase travel with larger values.
Navigate and set:
Functions > OK > End points > OK > UP/DOWN > OK > ... > OK (long)
End points
Ch1
100% 100%
Ch2
100% 100%
Ch3
100% 100%
Ch4
100% 100%
Ch5
100% 100%
Ch6
100% 100%
[ Fig. 6
]) . Set the channels according to your
5
6
Fig. 6
[ Fig. 7
]). Reduce travel with
Fig. 7

Advertisement

Table of Contents
loading

Related Products for Conrad Electronic RC Logger R8

This manual is also suitable for:

Rc logger rcl-rr8-tp89102rc

Table of Contents