RE614 Smoke Alarm
protection device that alarms when it
detects smoke or temperatures above
135°F (57°C).
Features
• UL217 and ULC531 listings
• Smoke and heat detection
• 5 year warranty
Quick Start Guide
1. Remove the mounting plate.
2. Pull the battery tab.
3. Restore the mounting plate and
twist it fully onto the smoke alarm.
Note: Enrollment is possible only
if the mounting plate is twisted
onto the smoke alarm.
4. Enroll the smoke alarm by placing
the panel into wireless enrollment
mode and then holding down the
smoke's test button until the smoke
alarm beeps.
5. Remove the mounting plate and
refer to Sections 2 and 6 for
positioning and installation.
6. After mounting plate is installed
restore the smoke alarm onto the
mounting plate and fully test the
smoke alarm per Section 7.
Alternate Enrollment Methods
• Scan the smoke alarm's bar code
using the Connect+ Installer app,
OR
• Enter the 8-character serial
number on the interactive service
provider's web portal.
To replace the battery,
smoke alarm from its mounting plate
and replace the batteries.
This manual should be read prior to use and retained for further information.
Use the Panel's installation guide to verify proper system setup.
RE614 Smoke Alarm
Connect+
is a fire-
detach the
Attention
Compatible
Pull Battery Tab
12 inches
minimum
Position Smoke Alarm
Test Smoke Alarm
I
12 inches
minimum

Advertisement

Table of Contents
loading

Summary of Contents for Resolution RE614

  • Page 1 RE614 Smoke Alarm Connect+ Compatible ™ RE614 Smoke Alarm is a fire- protection device that alarms when it detects smoke or temperatures above 135°F (57°C). Features • UL217 and ULC531 listings • Smoke and heat detection • 5 year warranty Quick Start Guide 1.
  • Page 2 Indicator Summary Normal Operation Action Red LED Yellow LED Sounder Power Up Insert Battery 1 Flash 1 Flash Standby Sensing Fire Rapid Flashing Full Sound Fault Mode Action Red LED Yellow LED Sounder Low Battery 1 Flash every 48 sec 1 Beep Faulty Smoke Sensor 2 Flashes every 48 sec...
  • Page 3: Location And Positioning

    The installation of smoke detectors in kitchens, benefits that the user is reminded every 10 attics (finished or unfinished), or garages is minutes by two short beeps that the Alarm not normally recommended, as these locations needs to be replaced and that if the problem occasionally experience conditions that can clears the Alarm will return to detecting fire).
  • Page 4 Locate Heat Alarms in rooms adjoining escape room is the most likely place for a fire to start routes - kitchens, garages, boiler houses etc. at night, followed by the kitchen (where a where Smoke Alarms are unsuitable. Heat Alarm is recommended) and then the dining room.
  • Page 5: Fire Safety Advice

    preclude ceiling mounting. It is considered to • Near a decorative object, door, light fitting, be the responsibility of the installer/client to window moulding etc., that may prevent determine if the presence of asbestos in the smoke from entering the Alarm. ceiling material would make ceiling mounting •...
  • Page 6: Alarm Limitations

    a repair - see section 5 ‘Getting Your Alarm Serviced’. • This appliance is intended ONLY for premises having a residential type environment. • This is not a portable product. It must be mounted following the instructions in this instruction leaflet. •...
  • Page 7: Getting Your Alarm Serviced

    chimney, in a wall cavity, or if the prevailing 3. Place the mounting plate on the ceiling air draughts carry the smoke or heat away. exactly where you want to mount the Alarm. Installing Smoke Alarms on both sides of closed With a pencil, mark the location of the two doors and installing more than one Alarm as screw holes.
  • Page 8: Power Supply Monitoring

    Alarm (see Figure 7b). To remove the Alarm from the ceiling, remove the screw first, and then twist off Figure 7a - How to Tamperproof anti-clockwise. 7. Testing, Maintenance and BREAK OFF SMALL PILLAR Power Supply Monitoring Your Alarm is a life saving device and should be checked periodically.
  • Page 9 condition). Replace battery with Panasonic CR123A, use of another battery may present a risk of fire The Smoke Alarms will be silenced for a period or explosion. of approximately 10 minutes. The red light on the cover of the Smoke Alarm will flash every 7.4 Cleaning your Alarm 8 seconds to indicate that the unit has been Clean your Alarm regularly.
  • Page 10: Troubleshooting

    Figure 8b 8.6 Smoke Alarm Automatic Self-Test The smoke chamber in the Smoke Alarms automatically tests itself every 16 seconds. If the chamber is degraded it will beep twice every 48 seconds with 2 yellow LED flashes at the same time. If this happens clean the unit. If the beeping persists and the beep does not coincide with a yellow light flash, return the unit for service (see Section 5 - Getting Your...
  • Page 11 • If necessary replace the battery or batteries with Panasonic CR123A. 9. System Compatibility and Wireless Verification Smoke alarm model RE614 has only been evaluated at ETL with Alula Connect+ Model#: RE6100. Test the system after finishing installation, enrollment, and configuration. Verify...
  • Page 12 85 dBA at 10 feet (3m) minimum Smoke Sensitivity 1.95% to 4% OBS/Foot Heat Sensor 135 ± 5°F (57 ± 2°C) Certiication RE614 FCC, IC, UL217, ULC531 Speciications subject to change without notice. WARRANTY IC NOTICE Alula will replace non-portable products that are...