Resolution RE114 Manual

Interlogix compatible smoke and heat alarm

Advertisement

Quick Links

RE114 Interlogix
Smoke Alarm
that alarms when it detects smoke or
temperatures above 135°F (57°C).
Features
• UL217 and ULC531 listings
• Smoke and heat detection
• 5 year warranty
Quick Start Guide
1. Remove the mounting plate.
2. Pull the battery tab.
3. Enroll the smoke alarm by placing
the panel into wireless enrollment
mode and then twisting the smoke
onto the mounting plate.
Note: Enrollment transmissions are
sent when the mounting plate is
twisted onto the smoke alarm.
4. Remove the mounting plate and
refer to Sections 2 and 6 for
positioning and installation.
5. After mounting plate is installed
restore the smoke alarm onto the
mounting plate and fully test the
smoke alarm per Section 7.
To replace the battery,
smoke alarm from its mounting plate
and replace the batteries.
This manual should be read prior to use and retained for further information.
Verify proper enrollment and operation using your security panel's installation manual.
®
Compatible Smoke and Heat Alarm
is a fire-protection device
detach the
12 inches
minimum
Attention
Pull Battery Tab
12 inches
minimum
Position Smoke Alarm
Test Smoke Alarm
I

Advertisement

Table of Contents
loading

Summary of Contents for Resolution RE114

  • Page 1 ® RE114 Interlogix Compatible Smoke and Heat Alarm Smoke Alarm is a fire-protection device that alarms when it detects smoke or temperatures above 135°F (57°C). Features • UL217 and ULC531 listings • Smoke and heat detection • 5 year warranty Quick Start Guide 1.
  • Page 2 Indicator Summary Normal Operation Action Red LED Yellow LED Sounder Power Up Insert Battery 1 Flash 1 Flash Standby Sensing Fire Rapid Flashing Full Sound Fault Mode Action Red LED Yellow LED Sounder Low Battery 1 Flash every 48 sec 1 Beep Faulty Smoke Sensor 2 Flashes every 48 sec...
  • Page 3: Location And Positioning

    The installation of smoke detectors in kitchens, benefits that the user is reminded every 10 attics (finished or unfinished), or garages is minutes by two short beeps that the Alarm not normally recommended, as these locations needs to be replaced and that if the problem occasionally experience conditions that can clears the Alarm will return to detecting fire).
  • Page 4 Locate Heat Alarms in rooms adjoining escape room is the most likely place for a fire to start routes - kitchens, garages, boiler houses etc. at night, followed by the kitchen (where a where Smoke Alarms are unsuitable. Heat Alarm is recommended) and then the dining room.
  • Page 5: Fire Safety Advice

    preclude ceiling mounting. It is considered to • Near a decorative object, door, light fitting, be the responsibility of the installer/client to window moulding etc., that may prevent determine if the presence of asbestos in the smoke from entering the Alarm. ceiling material would make ceiling mounting •...
  • Page 6: Alarm Limitations

    a repair - see section 5 ‘Getting Your Alarm Serviced’. • This appliance is intended ONLY for premises having a residential type environment. • This is not a portable product. It must be mounted following the instructions in this instruction leaflet. •...
  • Page 7: Getting Your Alarm Serviced

    chimney, in a wall cavity, or if the prevailing 3. Place the mounting plate on the ceiling air draughts carry the smoke or heat away. exactly where you want to mount the Alarm. Installing Smoke Alarms on both sides of closed With a pencil, mark the location of the two doors and installing more than one Alarm as screw holes.
  • Page 8: Power Supply Monitoring

    Alarm (see Figure 7b). To remove the Alarm from the ceiling, remove the screw first, and then twist off Figure 7a - How to Tamperproof anti-clockwise. 7. Testing, Maintenance and BREAK OFF Power Supply Monitoring SMALL PILLAR Your Alarm is a life saving device and should be checked periodically.
  • Page 9 condition). Replace battery with Panasonic CR123A, use of another battery may present a risk of fire The Smoke Alarms will be silenced for a period or explosion. of approximately 10 minutes. The red light on 7.4 Cleaning your Alarm the cover of the Smoke Alarm will flash every 8 seconds to indicate that the unit has been Clean your Alarm regularly.
  • Page 10: Troubleshooting

    The latest design, materials and manufacturing techniques have been used in the construction of Resolution Products’ Alarms to minimise the effects of contamination. However it is impossible to completely eliminate the effect of dust and insect contamination, and...
  • Page 11 • If necessary replace the battery or batteries with Panasonic CR123A. 9. System Compatibility and Wireless Verification Smoke alarm model RE114 has only been evaluated at ETL with Interlogix Simon XTi Model#: 60-924-RF-TS Test the system after finishing installation, enrollment, and configuration. Refer the panel’s manual for instructions on testing the...
  • Page 12: Specifications

    This device complies with Industry Canada license- Changes or modifications not expressly approved by exempt RSS standard(s). Operation is subject to the the Resolution Products, Inc. could void the user’s following two conditions: authority to operate this equipment. (1) This device may not cause interference, and...