Installing a 4-wire conduit
• Aluminum building wire may be used but it must be rated for the correct amperage
and voltage to make the connection. Connect the wires as described below.
• The wire you use, the location and enclosure of splices, etc., must conform to good
wiring practices and local codes.
1. Loosen the 3 lower terminal screws from the terminal block. Remove the
ground screw and ground plate and retain them.
2. Cut and discard the ground strap. Do not discard any screws.
3. Insert the ground bare wire tip between the range frame and the ground
plate (removed earlier) and secure it in place with the ground screw (removed
earlier).
4. Insert the bare wire (white/neutral) tip through the bottom center of the terminal
block opening.
5. Insert the two side bare wire tips into the lower left and the lower right terminal
block openings.
6. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not
over-tighten the screws since it could damage the wires.
7. Go to Step 5 on page 15 to continue with the installation.
Ground strap
Ground plate
CAUTION
CAUTION
Live 1 - Neutral
120 V
Live 2 - Neutral
120 V
Live 1 - Live 2
208 V / 240 V
Live 1
Wire tips
You must check voltage after connecting power cord.
English - 15
Red
Black
White
White
Black
Neutral
terminal
Live 2
Red
Ground
wire
(Green)