Installing a 3-wire power cord
WARNING
WARNING
connected to the neutral terminal located in the center of the terminal block. The power
leads must be connected to the lower left and the lower right terminals of the terminal block.
1. Remove the 3 lower terminal
screws from the terminal block.
2. Insert the 3 terminal screws
through each power cord terminal
ring and into the lower terminals
of the terminal block. Be certain
that the center wire (white/neutral)
is connected to the center lower
position of the terminal block.
3. Tighten screws securely to
the terminal block. DO NOT
remove the ground strap
connection.
4. Go to Step 5 on page 15 to
continue with the installation.
CAUTION
CAUTION
Live 1 - Neutral
120 V
Live 2 - Neutral
120 V
Live 1 - Live 2
208 V / 240 V
The neutral or ground wire of the power cord must be
Neutral
terminal
Live 1
You must check voltage after connecting power cord.