Hoshizaki KM-1301SWJ/3 Service Manual page 47

Modular crescent cuber
Hide thumbs Also See for KM-1301SWJ/3:
Table of Contents

Advertisement

11. Minimum Harvest Time (S5 dip switch 4)
Factory set for proper operation. Do not adjust. Adjustment outside the factory
default setting may result in damage to the appliance.
12. Anti-Slush (S5 dip switch 5)
This dip switch setting provides anti-slush control during the freeze cycle. When the
evaporator temperature reaches 36°F (2.2°C) the control board reads a 5.8kΩ signal
from the thermistor and de-energizes the water pump for 10 sec. to melt ice slush and
prevent ice slush from blocking the water supply tubing, causing irregular freeze patterns.
Factory set for proper operation. Do not adjust. Adjustment outside the factory
default setting may result in damage to the appliance.
NOTICE
S5 Dip Switch Setting
No. 4
OFF
ON
NOTICE
S5 Dip Switch Setting
No. 5
OFF
ON
47
Minimum
Harvest Timer
120 sec.
70 sec.
Anti-Slush
Disabled
Enabled

Advertisement

Table of Contents
loading

Table of Contents