Operating the appliance
en
Automatic mode
Switching on
Touch the
symbol.
#
The fan will start at setting 2.
Touch the
symbol.
!
The optimum fan setting is set automatically using
an air quality sensor.
Switching off
Touch the
or
symbol to switch off automatic
!
#
mode.
The fan will switch itself off automatically if the air quality
sensor detects no further change in the air quality in the
room.
Automatic mode can run for a maximum of four hours.
Sensor control
In automatic mode, an air quality sensor in the extractor
hood detects the intensity of the cooking and roasting
odours. Depending on the air quality sensor setting, the
fan will switch itself to another fan setting automatically.
Possible sensor settings:
Default sensitivity setting:
Lowest sensitivity setting:
Highest sensitivity setting:
If the sensor controller responds too strongly or not
enough, it can be changed accordingly:
Touch and hold the
1.
when the fan is switched off. The setting will be
displayed.
Slide your finger across control panel III to change
2.
the sensor control setting.
Take your finger off the
3.
Fan run-on time
Switching on
If intensive mode has been activated, the run-on
Note:
function will not be available.
Touch the
A
symbol until
panel.
The fan will run at fan setting 1.
After approximately 10 minutes, the fan will switch itself
off automatically.
Switching off
Slide your finger to the right across control panel III until
a fan setting lights up in the display.
This immediately stops fan run-on.
8
symbol for one second
!
!
symbol.
x
lights up on the display
Saturation display
If the metal grease filters or the activated charcoal filter
are/is saturated, the corresponding symbols flashes
after the appliance is switched off:
Metal grease filters:
Activated charcoal filter:
Metal grease filters and activated charcoal filter:
and
"
If you have not yet done so, the metal grease filters
should now be cleaned or the activated charcoal filter
replaced. ~ "Cleaning and maintenance" on page 12
The saturation indicator does not apply for non-
Note:
renewable activated charcoal filters that are inserted
downstream of the metal grease filter. These activated
charcoal filters must be replaced twice a year.
The saturation indicators can be reset while they are
flashing. Slide your finger to the left across the control
panel to do so.
Switching over the display for air recirculation mode
For air recirculation mode, the electronic controller must
be switched over accordingly:
The extractor hood must be connected and switched
off.
Touch and hold the
same time until "2" lights up for air recirculation
mode (filters that cannot be regenerated).
Repeatedly touching and holding this button
combination makes "3" light up for air recirculation
mode (filters that can be regenerated).
Repeatedly pressing and holding this button
combination switches the electronic controller back
over to air extraction mode ("1" ).
Audible signal
Switching on
Touch and hold the
#
for approximately 3 seconds when the fan is switched
off. An audible signal will sound as an
acknowledgement.
When the signal tone is activated,
Switching off
Touch and hold the
#
for approximately 3 seconds when the fan is switched
off. An audible signal will sound as an
acknowledgement.
When the signal tone is deactivated,
!
"
and
symbols at the
#
!
and
symbols at the same time
&
will be lit.
and
symbols at the same time
&
will be lit.
!

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq300 lc91buv50b

Table of Contents