Connections
(continued)
System example 2 (connection with commercially available controller,
RS-422 connection)
● Configure the service switches at the bottom of the unit.
For details on the service switches, see "Service switch settings" (page 42).
SW1
Camera address
SW2
setting (standard
serial communication)
SW3
Communication
SW4
format
Communication baud
SW7
rate
Communication
SW8
connector
● Configure the following items in the camera menu.
1. Display [System] menu  [Protocol]  [Model Select].
2. Select [SEVIHD1], [SBRC300], or [SBRCZ330] for the protocol type.
Note
● Daisy-chain connections are not possible for RS-422 connections.
AW-HN40/AW-HN38
Supplied AC adaptor
Set to AUTO or 1 to 7.
(Set address numbers so that they do not duplicate each other.)
Enable standard serial communication (ON).
Set to 9600 bps (OFF) or 38400 bps (ON) based on your commercially
available controller.
Set to RS-422 (OFF).
RS-422 communication connector
Commercially
available controller