Drain hose installation
1. If necessary, connect the 2-meter extension drain hose to the drain hose.
2. If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.
3.
tightly with a clamp.
• If you do not use the other drain hose hole, block it with a rubber stopper.
4. Pass the drain hose under the refrigerant pipe, keeping the drain hose
tight.
5. Pass the drain hose through the hole in the wall. Check if it slants
downwards as seen in the picture.
• The hose will be
36 for further details.
• Make sure the installed direction of the drain hose is correct.
Inadequate installation may cause condensate water leakage.
• If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the
• DO NOT WALL UP THE DRAIN HOSE CONNECTION !
Drain hose connection must be easy accessible and serviceable.

Changing direction of the drain hose

Change the direction only when it is necessary.
1. Detach the rubber cap with the plier.
2. Detach the drain hose by pulling it and turning to the left.
3.
hose and the outlet of the drain pan.
4. Attach the rubber cap with a screwdriver by turning it to the right until it
5. Check for leakage on both side of the drain outlet.
Pour the water in direction of arrow.
• Make sure the indoor unit is in upright position when you pour water to check for leakage.
32
permanently into position after
 Direction of the drained water
Drain hose hole
Shield
Drain hose
Extension drain hose
the installation and the gas leak test; refer to page
Screw hole
Screw
Drain hose
Drain pan outlet
Rubber cap