Technical data
Display
Measuring frequency
Measuring impedance
Operating voltage
Working conditions
Operating altitude
Storage conditions
Weight
Dimensions (LxWxH)
Opening width current sensor
Over-voltage category
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of
smallest points)). The accuracy is valid for one year at a temperature of +23°C ±
5°C, and at a relative humidity of less than 75 %, non-condensing.
Alternating current (AC/A)
Range 50-60 Hz
600.0 A
1000 A
Range 60-400 Hz
600.0 A
1000 A
Direct current (DC/A) VC-531 only
Range
600.0 A
1000 A
50
6000 counts
approx. 2 measuring operations/second
>10MΩ (V range)
9 V block battery
5°C to 40°C; max. 80% RH
max. 2,000 m
-20°C to +60°C; max. 80% RH
ca. 271 g
232 x 77 x 39 (mm)
40 mm
CAT III 600 V
Accuracy
±(3,5 % + 10)
±(3,8 % + 10)
Accuracy
±(6 % + 12)
±(7 % + 12)
Accuracy
±(3,5 % + 10)
±(3,8 % + 10)
Definition
100 mA
1 A
Definition
100 mA
1 A
Definition
100 mA
1 A