INITIAL FILL & HEAT
CAUTION - The dispenser must be disconnected from the power source throughout the initial set-up, except when speci-
fied in the instructions.
1. Turn-on the water supply and connect the dispenser to the power source.
2. Water will automatically flow into the tank to the proper level and then shut-off. This will take less than five minutes.
3. When the tank is full of water, open the front door and place the heater switch in the "ON" (lower) position. A tank
full of cold water will take approximately eighty minutes for the water to heat on 120 volt versions or forty minutes for
120/208 volt versions, 120/240 volt versions, and 220-240 volt versions.
During this waiting period, complete these dispenser set-up steps:
a. Place the drip tray in front of the dispenser. Set the drip tray cover in place.
b. Place a set of keyholes in the cup locator plate over the screws beneath the hopper access door and push down gently.
c. Fill the hoppers with the dry product to be dispensed.
PRESET TANK TEMPERATURE
Tank temperatures have been preset at the factory to 180°F (82°C). Bunn recommends that to provide the best quality
beverage, the installer adjust the tank temperature to the powder product manufacturer's recommended temperature for
the hot powder product being used.
LIQUID LEVEL CONTROL
The system automatically maintains the hot water tank's level by energizing the refill solenoid when the water level
drops below the liquid level probe. If the system has not successfully refilled in 15 minutes, a refill error occurs. When a
refill error occurs, the refill solenoid is de-energized and the left rinse L.E.D. will flash about once every 5 seconds. Once
the cause of the refill error has been investigated (see the troubleshooting guide in the Operating and Service Manual)
and cured, the system can be reset by placing the Rinse/Run switch in the programming (center) position, momentarily.
RINSE TIMERS
The dispenser is shipped from the factory with the rinse timers disabled. To enable the rinse timers, remove power
from the dispenser, remove the lower access panel, and remove the jumper from J1 of the control boards. Replace the
lower access panel, and return power to the dispenser. When enabled, the rinse timers automatically keep track of the
time since the dispenser was last run through a rinse sequence. If the dispenser detects that a rinse sequence has not been
run for 8 hours, the appropriate rinse L.E.D. will flash continually. If, after an additional 4 hours (12 hours total), a rinse
sequence has still not been run, the appropriate rinse L.E.D. will light continuously, and the appropriate hopper drives will
be disabled until a rinse sequence has been run.
RUNNING A RINSE SEQUENCE
1. Place the rinse/run switch in the rinse position.
2. Sequentially, or simultaneously, at each of the positions dispense for at least 10 seconds.
3. After the rinse L.E.D. has extinguished, the rinse timer is reset.
4. Return the rinse/run switch to the run position.
DISPENSER USE
1.
Simply place a cup on the drip tray beneath the dispensing tip.
2.
Press the button and dispense the beverage.
3.
Release the button when the cup is approximately
NOTE - The whipper chamber must drain at the end of each dispense.
COLD BEVERAGE SET-UP (OPTIONAL)
Cold beverages may be dispensed from the left dispense position. Simply place the HOT/COLD switch near the left
whipper chamber in the "COLD" (upper) position.
/
full and allow the whipper chamber to drain.