6.4 Recommended settings

6.4.1 Standard parameter settings, recommended
setting ranges
The following table summarises the factory settings and the pos-
sible and recommended setting ranges of the Solaris R4 regu-
lator system parameters.
Parameter
TKpos
Solar panel
Delta T on
Switch-on temperature difference
Delta T off
Switch-off temperature difference
TS max
Maximum storage tank temperature
Minimum run time of the solar operating
time P2
pump P
Release blocked pump stages every 24
AUTORESET %P
hours
FLS active
FlowSensor activation
FR active
Status frost protection function
Automatic return from manual to auto-
H/A
matic operation
P min
Min. output for burner stop
Threshold solar panel temperature for
T frost
activation of the frost protection function
Threshold temperature for activation of
T frost off
the enhanced frost protection function
for solar panels
Booster temperature
TK max
(maximum solar panel temperature)
Minimum solar panel temperature fro
TK save
release of pump operation with active
frost protection function
Restart protection temperature (max.
TK permitted
permissible operating solar panel tem-
perature)
TR min
Minimum return temperature
Minimum storage tank temperature for
TS min
burner stop
Additional start run time of the solar
time frost
operating pump P
tection function
time SP
Blocking time solar operating pump P
time VBSK
Delay burner blocking contact
Tab. 6-5 Overview of parameters
FA ROTEX Solaris RPS4 - 04/2016
Designation
at maximum output
S
with active frost pro-
S
Access level Setting range Recommended
Specialist
3...80
(>"Delta off")
1...14
(>"Delta on")
Operator
20 to 85°C
10 to 999 kW Filling time +20 s
Yes/No
0 to 100
Yes/No
1 to 900 min
0,0 to 99.9 kW
0 to 10°C
-5
20 to 110°C
50 to 150°C
90 to 250°C
10 to 60°C
0 to 99°C
0 to 600 s
0 to 600 s
S
10 to 600 s
6
x
FlowSensor
Factory
setting range
setting
Real
mounting posi-
tion
10 to 15 kW
15 K
2 to 5 kW
2 K
75 to 85°C
80°C
150 s
No
FLS 12: 12
With FLS:
FLS 20: 20
20
FLS 100: 100
No
30 min
99.9 kW
0°C
-5°C
75°C
70°C
95°C
25°C
99°C
0 s
30 s
120 s
Increment
15 K
1 K
1 K
1 s
0, 12, 20,
100
1 min
0.1 kW
1 K
1 K
1 K
1 K
1 K
1 K
1 s
10 s
10 s
29