Error code
E11
Fill time too long.
E13
Water leak in tub or air leak in air bell.
E14
Reed switch.
E21
Water not pumping out fast enough.
E23
Drain pump relay on control board failed.
E24
Drain pump relay on control board failed.
E31
Better models. Pressure sensor not communicating
with control board.
E35
Better models. Pressure sensor indicates water overfill.
E41
Control board thinks the door switch is open.
E42
Door remains locked after cycle is completed.
E43
Control board problem.
E44
Control board problem.
E45
Control board problem.
E46
Control board problem.
E47
Board thinks the door PTC circuit is open in spin.
E48
Board thinks the door PTC circuit is closed.
E52
Bad signal from tacho generator.
E55
Motor overheating.
E56
High motor current.
E57
High current on inverter.
E58
High current on motor phase.
E59
No tacho signal for 3 seconds.
E5A
High temperature on heat sink.
E5B
High temperature on heat sink.
E5C
High temperature on heat sink.
E5D
Communication problem.
E5E
Communication problem.
E5F
Communication problem.
E67
Input voltage on microprocessor incorrect.
E75
Better models only. Water temperature sensor circuit.
E76
Better model only. NTC temperature for the cold water
valve over the limits.
E95
Communication error.
EB1
Incoming power frequency out of limits.
EB2
Incoming line voltage above 130 VAC.
EB3
Incoming line voltage below 90 VAC.
EF1
Clogged drain pump.
EF2
To much soap.

Error code chart

Fault condition
3
Check
Refer to test (1).
Refer to test (2).
Refer to test (3).
Refer to test (4).
Replace control board.
Replace control board.
Refer to test (5).
Refer to test (6).
Refer to test (7).
Refer to test (8).
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Refer to test (9)
Refer to test (9)
Refer to test (10)
Refer to test (11)
Refer to test (11)
Refer to test (11)
Refer to test (11)
Refer to test (12)
Replace the speed control
board.
Replace the speed control
board.
Replace the speed control
board.
Refer to test (13)
Refer to test (13)
Refer to test (13)
Replace the control board.
Refer to test (14)
Hot and cold water hoses
switched.
Replace the control board.
Refer to test (15)
Check voltage at the outlet. If
below 130 VAC, replace the
control board.
Check voltage at the outlet. If
above 90 VAC, replace the
control board.
Unclog the drain pump.
Advise customer to reduce
the amount of soap they are
using.