Error Code Chart - Frigidaire ATFB7000ES1 Technical Data Sheet

Frigidaire atfb7000es1: data sheet
Table of Contents

Advertisement

Available languages

Available languages

Error
code
E11
Fill time too long.
E13
Water leak in tub or air leak in air bell.
E21
Water not pumping out fast enough.
E23
Drain pump relay on control board failed or wire off pump.
E24
Drain pump relay on control board failed or wire off pump.
E31
Pressure sensor not communicating with control board.
E35
Pressure sensor indicates water overfill.
E36
Control board problem.
E41
Control board thinks the door switch is open.
E43
Control board problem.
E44
Control board problem.
E45
Control board problem.
E46
Control board problem.
E47
Board thinks the door PTC circuit is open in spin.
E48
Board thinks the door PTC circuit is closed.
E52
Bad signal from tacho generator.
E56
High motor current.
E57
High current on inverter.
E58
High current on motor phase.
E59
No tacho signal for 3 seconds.
E5A High temperature on heat sink caused by overloading.
E5B High temperature on heat sink.
E5C High temperature on heat sink.
E5D Communication problem.
E5E Communication problem.
E5F
Communication problem.
E66
Heating element relay failure.
E67
Input voltage on microprocessor incorrect.
E68
Current leakage to ground on heater or fuse opened.
E71
Wash NTC failure. (Tub heater)
E74
Wash temperature does not increase.
E75
Water temperature sensor circuit.
E76
NTC temperature for the cold water valve over the limits.
E82
Console control problem.
E83
Console control problem.
E91
Comunnication error between UI board and control board.
E93
Console control problem.
E94
Console control problem.
E95
Communication error.
E97
Console control problem.
E98
Console control problem.
EB1 Incoming power frequency out of limits.
EB2 Incoming line voltage above 130 VAC.
EB3 Incoming line voltage below 90 VAC.
EF1
Clogged drain pump.
EF2
Too much soap.
EBE Console control problem.
EBF Console control problem.
EF5
NTC temperature for the hot water valve over the limits.

Error code chart

Fault condition
2
Check
Refer to test (1).
Refer to test (2).
Refer to test (3).
Replace control board or wire.
Replace control board or wire.
Refer to test (4).
Refer to test (5).
Replace the control board.
Refer to test (6).
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Refer to test (7).
Refer to test (7).
Refer to test (8).
Refer to test (9).
Refer to test (9).
Refer to test (9).
Refer to test (10).
Test first-if bad-rpl speed control brd.
Replace the speed control board.
Replace the speed control board.
Refer to test (11).
Refer to test (11).
Refer to test (11).
Refer to test (14).
Refer to test (15).
Refer to test (14).
Replace control board or wire.
Place NTC in correct position.
Refer to test (12).
Hot and cold water hoses switched.
Replace the control board.
Replace the control board.
Check wiring.
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Replace the control board.
Refer to test (13)
Check voltage at the outlet. If below
130 VAC, replace the control board.
Check voltage at the outlet. If above
90 VAC, replace the control board.
Unclog the drain pump.
Advise customer to reduce the amount
of soap they are using.
Replace the control board.
Replace the control board.
Hot and cold water hoses switched.