Outdoor Unit Installation

Step 3.1 Fixing the outdoor unit in
place
Rubber leg
Model
90
12/18
24
1
Place the outdoor unit as directed on the top of the
unit to let the discharged air out properly.
2
Fix the outdoor unit in level to an appropriate support
using anchor bolts.
NOTE
• Secure the rubber legs to help prevent the generation
of noise and vibration.
• If the outdoor unit is exposed to strong winds, install
shield plates around the outdoor unit so that the fan
can operate correctly.
40 English
RAC MEDIA ODM 아프리카향 IBIM_EN_DB68-00000A-00.indb 40
X
(Unit : mm)
X
Y
700
275
770
300
845
363
Optional: Fixing the outdoor unit to a wall with
a rack
Soft rubber designed to cut off vibration from
rack to wall (not supplied with product)
Soft rubber designed to cut off residual vibration
from outdoor unit to rack (not supplied with product)
NOTE
• Make sure that the wall can support the weights of the
rack and the outdoor unit.
• Install the rack close to the column as much as
possible.
Step 3.2 Connecting the cables and
the refrigerant pipes
09/12/18
To indoor unit
CAUTION
• Be sure to fix the power cables and communication
cable with a cable clamp.
24
To indoor unit
2017-01-20 오전 11:28:47