Pepperl+Fuchs LS670-DA Manual
Pepperl+Fuchs LS670-DA Manual

Pepperl+Fuchs LS670-DA Manual

Optical data coupler

Advertisement

Quick Links

FACTORY AUTOMATION
MANUAL
LS670-DA
Optical data coupler
R

Advertisement

Table of Contents
loading

Summary of Contents for Pepperl+Fuchs LS670-DA

  • Page 1 FACTORY AUTOMATION MANUAL LS670-DA Optical data coupler...
  • Page 2 LS670-DA With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation...
  • Page 3: Table Of Contents

    LS670-DA Contents 1 Introduction................. 4 Product documentation on the internet............5 2 Declaration of conformity ..........6 3 Safety ................... 7 Symbols relevant to safety ................7 Intended use ....................7 General safety instructions ................8 4 Product Description ............10 Use and application ..................10 Displays and controls..................11...
  • Page 4: Introduction

    Introduction Introduction Congratulations You have chosen a device manufactured by Pepperl+Fuchs. Pepperl+Fuchs develops, produces and distributes electronic sensors and interface modules for the market of automation technology on a worldwide scale. Before you install this device and put it into operation, please read the operating instructions thoroughly.
  • Page 5: Product Documentation On The Internet

    LS670-DA Introduction Product documentation on the internet You can view all the relevant documentation and additional information on your product at http://www.pepperl-fuchs.com. Simply enter the product name or model number in the Product/Key word search box and click Search. Select your product from the list of search results. Click on the information you require in the product information list, e.g., Technical documents.
  • Page 6: Declaration Of Conformity

    This product was developed and manufactured under observance of the applicable European standards and guidelines. Note! A Declaration of Conformity can be requested from the manufacturer. The product manufacturer, Pepperl+Fuchs GmbH, D-68307 Mannheim, has a certified quality assurance system that conforms to ISO 9001. ISO9001...
  • Page 7: Safety

    User modification and or repair are dangerous and will void the warranty and exclude the manufacturer from any liability. If serious faults occur, stop using the device. Secure the device against inadvertent operation. In the event of repairs, return the device to your local Pepperl+Fuchs representative or sales office.
  • Page 8: General Safety Instructions

    LS670-DA Safety General safety instructions Class 1M laser product This device is a class 1M laser product: Standards IEC 60825-1:2007 certified. Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007.
  • Page 9 If serious faults occur, stop using the device. Secure the device against inadvertent operation. In the event of repairs, return the device to your local Pepperl+Fuchs representative or sales office. Caution! Controls or adjustments...
  • Page 10: Product Description

    LS670-DA Product Description Product Description Use and application The optical data coupler serves as an optical link between two Ethernet devices; typically one is mobile. The opening angle is optimized for operations in high rack storage. With the optical data coupler, devices with industrial Ethernet topologies, such as PROFINET, Ethernet/IP and other Ethernet protocols, can be connected.
  • Page 11: Displays And Controls

    LS670-DA Product Description Displays and controls S I G N A L OVERLOAD LASER ERROR Lights up when the device is connected to the supply voltage. Status of the overall connection. Lights up if the signal is not strong enough to establish a connection (if misaligned or if the light beam is obstructed) and also when there is a fault on the optical channel, e.g., as a result of extraneous light.
  • Page 12: Interfaces And Connections

    LS670-DA Product Description Interfaces and connections The device includes the following connections: Power supply There is an 4-pin M12 connector on the rear of the housing to connect the power supply and the alarm output. The following diagram shows the pin assignment: Figure 4.1...
  • Page 13: Delivery Package

    LS670-DA Product Description Delivery package LS670-DA Optical data coupler ■ Leaflet ■ Accessories 4.5.1 Mounting accessories The following mounting accessories are available. Designation Description OMH-LS610-01 Alignment/mounting aid OMH-LS610-02 Direct mounting set (4 M4 threaded inserts) Protective cap LS610 Additional fastening for transport and storage.
  • Page 14: Installation

    2. Check that all items are present and correct based on your order and the shipping documents. If you have any questions, please contact Pepperl+Fuchs. 3. Keep the original packing material in case you need to store or ship the unit at a later time.
  • Page 15: Connection

    LS670-DA Installation Mounting on a P+F adjustment device The mounting accessories (OMH-LS610-01) consist of a mounting bracket and an integral alignment device (in x and y axes). The required beam direction (± 90° rotation) can be set using the mounting accessories, which are fastened to the mounting bracket using two M4 screws and the central M6 screw.
  • Page 16: Storage And Transport

    LS670-DA Installation Grounding / Shielding This type of grounding is not protective grounding, it acts solely as a down conductor for cable-related faults and is not subject to any safety guidelines (e.g. personnel protection). Functional grounding of the shields is required to provide immunity to interference.
  • Page 17: Commissioning

    LS670-DA Commissioning Commissioning Adjustment Alignment aid/ signal strength An alignment LED, which can be seen from a long way off, is located on the front panel as an alignment aid. As soon as a receiver detects the transmitter light of the device opposite it, the flashing frequency of the alignment aid decreases.
  • Page 18 LS670-DA Commissioning Aligning using the adjustment alignment aid The beam axis is aligned in the x and y direction using the two adjustment screws (hollow, 5 mm). This position is then fixed by tightening the central screw. Ethernet data communication is not needed for the alignment.
  • Page 19 LS670-DA Commissioning 6. We recommend to carry out the height adjustment before the lateral adjustment, as the height adjustment can mechanically modify the lateral position, but not the other way round. Once you have made the adjustments, tighten the central M6 screw to fix the position in the horizontal direction.
  • Page 20: Topology

    LS670-DA Commissioning Topology The optical data coupler does not contain any address routing logic (switch). This means that the distribution of the information must always be controlled by an external switch. The internal Ethernet adapter is permanently set to 100 MBit full duplex, as this is the only format that is converted for the optical transmission.
  • Page 21: Maintenance And Repair

    LS670-DA Maintenance and Repair Maintenance and Repair Maintenance To get the best possible performance out of your device, keep the optical unit on the device clean and clean it when necessary. Observe the following instructions when cleaning: Do not touch the optical unit with your fingers.
  • Page 22: Troubleshooting

    LS670-DA Troubleshooting Troubleshooting What to do in the event of an error Before requesting a service call, please check that the following actions have been taken: Test the equipment according to the following checklist. ■ Telephone assistance from the Service Center in order to isolate the ■...
  • Page 23: Appendix

    LS670-DA Appendix Appendix Technical data General specifications Effective detection 0 ... 150 m range Threshold detection 180 m range Light source laser diode Light type device F1 modulated infrared light Light type device F2 modulated visible red light Laser nominal ratings...
  • Page 24 LS670-DA Appendix Electrical specifications Operating voltage 18 ... 30 V DC No-load supply current 200 mA Data rate 7.5 MBit/s Interface Interface type 100 BASE-TX Output Pre-fault indication 1 PNP, inactive when falling short of the stability control , output short-circuit protected, max.
  • Page 25 Twinsburg, Ohio 44087 · USA Tel. +1 330 4253555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS • Printed in Germany TDOCT3571__ENG 12/2013...

This manual is also suitable for:

Ls670-da-en/f2Ls670-da-en/f1

Table of Contents