Pepperl+Fuchs LS600-DA-IBS Manual

Pepperl+Fuchs LS600-DA-IBS Manual

Optical data coupler

Advertisement

Quick Links

FACTORY AUTOMATION
MANUAL
Optical data coupler
LS600-DA-IBS
I
B
NTER
US

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LS600-DA-IBS and is the answer not in the manual?

Questions and answers

Summary of Contents for Pepperl+Fuchs LS600-DA-IBS

  • Page 1 FACTORY AUTOMATION MANUAL Optical data coupler LS600-DA-IBS NTER...
  • Page 2 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"...
  • Page 3: Table Of Contents

    Data light beam switches LS600-DA-IBS Introduction ................4 Warranty ................... 4 Declaration of Conformity............5 Safety ..................6 Symbols used ................... 6 General safety instructions ............... 6 Identification ................8 Data transmission ................8 Interface ................... 8 Function indicators: ................9 Mounting/Alignment ...............
  • Page 4: Introduction

    Warranty Pepperl+Fuchs manufactures its hardware products according to recognized industrial standards. Pepperl+Fuchs guarantees its products to be free of defects in material and workmanship provided the products are used under the normal operating conditions specified by the manufacturer. The warranty applies only to the original owner and is not transferable.
  • Page 5: Declaration Of Conformity

    Pepperl+Fuchs shall in no event be liable for consequential damages, concrete and indirect damages, secondary damages or penalties, or lost profits, sales, or loss of data, even if Pepperl+Fuchs had been made aware of this possibility.
  • Page 6: Safety

    Data light beam switches LS600-DA-IBS Safety Safety 3.1. Symbols used Safety-related symbols Danger! This symbol identifies an immediate and present danger. Failure to observe this warning may result in personal injury or even death. Warning! This symbol warns of a possible malfunction or hazard.
  • Page 7 Use only recommended original accessories. If you are unable to eliminate malfunctions, take the device out of operation. Secure the device against accidental operation. Return the device to Pepperl+Fuchs for repair. Own interventions and modifications are potentially hazardous, and any guarantee and man- ufacturer's liability shall become void.
  • Page 8: Identification

    Data light beam switches LS600-DA-IBS Safety Identification • Optical data transmission for InterBus-S. • Range: 0.5 m ... 200 m; /RT: 0.5 m ... 100m • Galvanically isolated interface • Baud Rate: 500 kBaud • Indication of status and functionreserve by LED´s •...
  • Page 9: Function Indicators

    Data light beam switches LS600-DA-IBS Safety Function indicators: Type plate 15,5 LED rt Function reserve simple LED ge Received data LED gn Transmitted data LED gn Function reserve multiple Signal label...
  • Page 10: Mounting/Alignment

    Data light beam switches LS600-DA-IBS Safety Mounting/Alignment The units are fixed into position by means of the mounting-bracket. On the upper side of the housing is a viewfinder for the telescopic sight which can be used for approximate alignment. The receivers lens of the opposite unit should be sigh- ted so that it lies next to the marked center.
  • Page 11: Electrical Connection

    Data light beam switches LS600-DA-IBS Safety Electrical connection Name Description (Data+) receiver (bus cable) /DI* (Data-) receiver (bus cable) GNDI* Data Ground insulated (Data+) driver (bus cable) /DO* (Data-) driver (bus cable) GNDI* Data Ground insulated /TX-DIS Emitter deactivation for 0 ... 1 V Stability control output, simple, PNP 0.1 A/ 30 V DC...
  • Page 12: Terminal Box

    Data light beam switches LS600-DA-IBS Safety Terminal box Switch positions: Shielding galvanically on ground potential housing capacitive coupling to ground potential / housing data inputs and outputs linked S2 and S3 normal operation mode Table 5.2: Switch positions Before mounting the optoelectronic device these switches must be off!
  • Page 13: Application Notes

    LS600-DA-IBS to the bus-system, which will be delayed, i.e. of 8 ... 10 µsec. The switch S1 inside the clamp block connects the shielding of the data-cable directly galvanically (ON) or with capactive coupling (OFF) via an capacitor 10 nF/630 V to hous- ing potential.
  • Page 14: Appendix

    Data light beam switches LS600-DA-IBS Appendix Appendix Technical data General specifications Effective detection range 0,5 ... 200 m (layout for operating range < 2 m see installation note) Option /35 0,5 ... 230 m Option /RT 0,5 ... 100 m...
  • Page 15: Dimensions With Mounting Bracket

    Data light beam switches LS600-DA-IBS Appendix Ambient conditions Ambient temperature -20 ... 50 °C (253 ... 323 K) Option /GUF -35 ... 50 °C (238 ... 323 K) with heated housing Storage temperature -20 ... 75 °C (253 ... 348 K)
  • Page 16: Diagrams

    Data light beam switches LS600-DA-IBS Appendix Diagrams Characteristic response curve LS 600-DA... Relative received light strength LS 600-DA Offset Y [mm] Stability control 1000 2000 1800 1600 1400 1200 1000 Distance X [m] Distance X [m] LS610-DA-.../35 LS610-DA-... Arrangement example of shelf causing advice...
  • Page 17: Wiring Example

    Data light beam switches LS600-DA-IBS Appendix Wiring example Outgoinig Interface LS600 connecting terminal Cable screen yellow green /DO2 grey /DI2 pink brown Switch: Help for installation fem. D-SUB 9 male_D-SUB_9 +24V LS600 Connecting terminal Incoming interface Cable screen yellow yellow...
  • Page 18: Notes

    Data light beam switches LS600-DA-IBS Appendix Notes...
  • Page 19 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"...
  • Page 20 Twinsburg, Ohio 44087 · USA Tel. +1 330 4253555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com DOCT-1849A 220570 Subject to modifications 11/2009 Copyright PEPPERL+FUCHS • Printed in Germany...

Table of Contents