Connecting To The Mains Terminal; Connecting To A Hob Or Cooker Point; Checking Electrical Connections - AEG COMPETENCE CD41001-A Operating Instructions Manual

Build-in electric multifunction double oven
Table of Contents

Advertisement

CONNECTING TO MAINS TERMINAL
WARNING: This appliance must be
earthed.
Make connection as shown in Fig. 7 by proceeding
as follows:-
Preform wires to the appropriate shape to suit fitting
into the mains terminal block.
Strip inner insulation on wires using wirestrippers.
Twist the bared wires using pliers.
Cut bared wires 10mm away from the end of the
inner insulation. Where uninsulated Earth wires are
used ensure they are suitably sheathed to leave
10mm bare wire to fit into the terminal.
Clamp bare wires into the relevant terminal and
check they are held by tugging each one in turn.
Clamp the mains cable securely ensuring 5mm of the
outer insulation is inside the terminal block and that
the wires are not taut but not so slack as to cause
any damage. See Fig. 7.
Place fuse/miniature circuit breaker in circuit and
switch on at mains.
CONNECTING TO A HOB OR COOKER
POINT
Either follow in general terms the instructions for
connecting to the terminal block or refer to the hob
suppliers installation instructions.
Feed the cable through the cabinet and
arrange to route the cable away from
the appliance which may become hot.

CHECKING ELECTRICAL CONNECTIONS

Correct electrical connection can be confirmed when
switching on the appliance as the timer will be
flashing.
NOTE: HOUSE CIRCUIT
Earth leakage and continuity tests must be carried out
before the appliance is connected to the mains supply
and re-checked after fitting.