Figure 6. Pull out the left side of the
amplifier and detach the flat cable from
the enclosure.
Figure 7. Remove the flat cable cover
plate and detach the flat cable connector.
Reattach the cover plate.
Figure 8. Remove the front mounting
ears.
The cloth must be acoustically transparent.
Genelec-approved cloth grilles are available.

Testing Mode

Once on, when the power button is pressed
for a long time, the RAM-L enters a mode for
system testing. This special mode is intended
for system debugging and testing. When the
RAM-L is turned off, the special mode is
reset. Upon restarting the RAM-L the current
standard settings stored by GLM software
are restored.
Test mode selection blinks the power
button light (see Table 2). A special mode
is activated by a long press on the power
button. In a special mode the power button
light remains on but blinks off 1-4 times indi-
cating the mode currently selected.
The testing modes are not intended for
continued operation. Use GLM software to set
up permanent settings for 1237A and 1238A.

Safety Considerations

The 1237A and 1238A have been designed
in accordance with international safety stand-
ards. To ensure continued safe operation and
to maintain the monitor under safe operating
conditions, the following warnings and pre-
cautions must be observed:
Figure 9. Attach the angled
rack mount ears.
Figure 10. Attach the front
plate.
1.
Servicing and adjustment must only be
performed by qualified service person-
nel. The monitor enclosure or the ampli-
fier enclosure must not be opened.
2.
Do not use this product with a mains
cable with no protective earth conduc-
tor, or a mains connection without the
protective earth contact, as this may
lead to personal injury.
3.
To prevent fire or electric shock, do not
expose the unit to water or moisture.
4.
Do not place any objects filled with
liquid, such as vases or water pipes on
the monitor or near it.
5.
Note that the amplifier is not completely
disconnected from the AC mains ser-
vice unless the mains power cord is
removed from the amplifier or the mains
outlet.
6.
Free flow of air behind the monitor is
necessary to maintain sufficient cool-
ing. Do not obstruct airflow around the
monitors.
WARNING!
The Genelec 1237A and 1238A monitors are
capable of producing sound pressure levels
in excess of 85 dB, which may cause perma-
nent hearing damage.