Technical specifications

Rated voltage
Rated frequency
Rated input
Protection against electric shock
Protections rating
Operating conditions
 
Spectrum of body attachment
Spectrum of facial attachment
Spectrum of bikini area attachment

Troubleshooting

Problem
The device/adapter
becomes warm during use
When I place the device on
the skin it does not release
a flash. The ' ready to flash
light blinks orange and
then lights up orange
continuously.
The 'ready to flash light'
doesn't light up when I
place the attachment on
my skin, but the cooling fan
works.
The 'ready to flash light'
lights up white but the
device does not produce a
flash when I press the flash
button.
This chapter summarizes the most common problems you could encounter
with the device. If you are unable to solve the problem with the information
below, visit www.philips.com/support for a list of frequently asked questions
or contact the Consumer Care Center in your country.
Possible cause
This is normal.
You skin tone in the area to
be treated is too dark.
The overheat protection has
been activated.
The device needs to be reset. To reset the device, switch it off and
100V-240V
50Hz-60Hz
36W
Class II
IP 30 (EN 60529)
Temperature:+15 ºC to 35 °C
Relative humidity: 30% to 95%
>530nm
>600nm
>530nm
Solution
No action required.
Treat other body areas with lighter skin
tones with Lumea.
When the overheat protection has been
activated, the fan still works. Do not
switch off the device, but let it cool down
for approx. 15 minutes before you
continue to use it.
switch it on again.