Q-T Ec Model Nomenclature; Table 1 Factory Built-In Electric Heat Table - Bard Q-TEC Q24H2D Series Installation Instructions Manual

Packaged air conditioner
Table of Contents

Advertisement

Q-T
Series General Information
ec
Q-T
MODEL NOMENCLATURE
ec
Q
36
H
MODEL
HEAT
NUMBER
PUMP
Q-TEC™
REVISION |
CAPACITY
24 - 2 Ton
30 - 2½ Ton
DEHUMIDIFICATION
36 - 3 Ton
REHEAT CYCLE
42 - 3½ Ton
48 - 4 Ton
VOLTS & PHASE |
60 - 5 Ton
A - 230/208/60/1
B - 230/208/60/3
C - 460/60/3
VENTILATION OPTIONS
X - Barometric Fresh Air Damper (Standard)
B - Blank-off Plate
V - Commercial Ventilator - Motorized w/Exhaust Spring Return
P - Commercial Ventilator - Motorized w/Exhaust Power Return
R - Energy Recovery Ventilator w/Independent Intake & Exhaust Control
NOTE:  If "X" control option is selected, then thermostat and humidistat, if applicable, or DDC control system must be field supplied.
At 240V 
Nominal
1-Ph
KW
KW
Amps
5.0
5.0
20.8
6.0
6.0
9.0
9.0
10.0
10.0
41.7
12.0
12.0
15.0
15.0
62.5
 These electric heaters are available in 230/208V units only.
 These electric heaters are available in 480V units only.
Manual 2100-603
Page
4 of 44
2
D
A
10
KW
0Z - 0KW
05 - 5KW
06 - 6KW
09 - 9KW
10 -10KW
12 -12KW
15 -15KW
FACTORY BUILT-IN ELECTRIC HEAT TABLE
(See Table 2 for Available Electric Heat by Unit Model)
At 208V 
3-Ph
1-Ph
BTUH
KW
Amps
Amps
17,065
3.75
18.0
14.4
20,478
4.50
21.7
30,717
6.75
34,130
7.50
36.1
28.9
40,956
9.00
36.1
51,195
11.25
54.1
X
X
FILTER OPTIONS
X - 1 inch Fiberglass
(Standard)
F - 2 inch Fiberglass
P - 2 inch Pleated
COLOR
V - Platinum w/Slate
Front (Vinyl)
X - Beige paint
4 - Gray paint
CLIMATE CONTROL OPTIONS
X - None 
E - Electronic/Prog/Man/Auto/Humidistat
I - Electronic/Prog/Man/Auto with CO
J - CS9BE-THO (BACnet IP or Ethernet)
K - CS9BE-THOC with CO
TABLE 1
At 480V 
3-Ph
BTUH
KW
Amps
12,799
12.5
15,359
6.0
18.7
23,038
9.0
25,598
25.0
30,717
12.0
31.2
38,396
15.0
X
X
COIL OPTIONS
X - Standard
1 - Phenolic coated
evaporator*
2 - Phenolic coated
condenser
3 - Phenolic coated
evaporator and
condenser coil*
*and reheat if
applicable
2
(BACnet IP or Ethernet)
2
At 460V 
3-Ph
3-Ph
BTUH
KW
Amps
Amps
7.2
20,478
5.52
6.9
10.8
30,717
8.28
10.4
14.4
40,956
11.04
13.9
18.0
51,195
13.80
17.3
X
X
INTERNAL
CONTROLS
X - Standard
• High Pressure Switch
• Low Pressure Switch
• Compressor Control
Module w/Time Delay
E - Low Ambient Control
Q - Outdoor Thermostat
R - Low Ambient Control
& Outdoor Thermostat
BTUH
18,840
28,260
37,680
47,099

Advertisement

Table of Contents
loading

Table of Contents