Acer PH530 Service Manual page 6

Hide thumbs Also See for PH530:
Table of Contents

Advertisement

Item
10
Brightness
11
System Controller
12
Video compatibility
13
Control keypad
14
Keystone correction
15
Contrast
16
Uniformity
17
Projection lens
18
Projection Image Size
19
LED indicator
20
Lamp life
21
Acoustic noise level
Confidential
- 700 ANSI Lumens ---typical.
- 590 ANSI Lumens ---engineering minimum.
- TI DDP 3020
- Standards :
NTSC - M, 4.43 MHz, 480i
PAL - B, D, G, H, I , M , N, 576i
SECAM - B, D, G, K, K1, L
HDTV - 480i, 480p, 576p, 720p, 1080i
- 8 Keys
POWER
ReSync
Menu
''Up''/''Down''/''Left''/''Right'' Direction Buttons
Source
- +/ - 6 degree
- 2200 : 1 Full On/Full Off ---typical
- 1500 : 1 Full On/Full Off --- engineering minimum
- 70% Japan standard (Minimum)
- 85% Japan standard (Typical)
- f = 22.29 mm ~ 26.72 mm, F/2.5 ~ 2.8, 1.2X Manual
Zoom Lens (YM10M)
- Adjustable from 33.55" to 310" -wide (Diagonal for
16:9)
- Power/Standby : Power ON /Stand-by status indicator
- Lamp : One-minute timer indicator to prevent the hot
re-strike
- Temp : Over-heat & Abnormal indicator
- 1500 hours min, 50% survival rate (Normal mode)
- 2000 hours min, 50% survival rate (Eco mode)
36 dB(A) ( Typical, Under 23±2
33 dB(A) (Typical, Under 23±2
Noise measurement follows ISO7779, A-weighted sound
pressure level measurement(refer appendix A), 7200
rpm color wheel rotational speed
1-2
Description
C; Normal mode )
0
C; Eco mode )
0
PH530