Installation requirements

Location requirements

Clearances and dimensions
NOTE
For OTR over Gas Stove, please follow local GAS CODE.
BEFORE YOU BEGIN to install this appliance, refer to the following information,
dimensions, and clearances. Do not locate the range where it may be subject
to strong drafts. Provide adequate clearances between the range and adjacent
combustible surfaces. These dimensions must be met for safe use of the range.
The location of the electrical outlet and gas piping may be adjusted to meet the
following dimensions and clearances.
For installation in Canada, a free-standing range is not to be installed closer than
4.7 in (12 cm) from any adjacent surface.
CAUTION
This range has been designed to comply with the maximum allowable wood
cabinet temperature of 194 °F (90 °C). Make sure the wall covering, countertops,
and cabinets around the range can withstand the heat (up to 194 °F [90 °C])
generated by the range. If not, discoloration, delamination, or melting may occur.
Side
30 in
Clearance
(76.2 cm)
Above
Cooking
Surface to
4 in
6 in
Wall
(10.2 cm)
(15.2 cm)
24 in
(61 cm)
36 in
Lower
(91.4 cm)
Cabinet
Depth
13 in (33 cm)
Overhead
Cabinet
Depth
30 in (76.2 cm)
18 in
(45.7 cm)
0 in (0 cm)
Clearance Below
Cooking Top and at
Rear and Sides of
Range
CAUTION
Do not grasp the knob, handle and push when you install.
CAUTION
DO NOT install the oven so that the door is flush with the cabinet.
For OTR over Gas Stove, please follow local GAS CODE.
Minimum dimensions
WARNING
0 in
(0 cm)
If overhead cabinets are provided, a range hood should also be provided that
projects horizontally a minimum of 5 in (12.7 cm) beyond the front of the cabinets.
This will dissipate any heat buildup in the overhead cabinets to prevent death,
personal injury, and/or fire hazard. The ventilating hood must be constructed of
sheet metal not less then 0.0122" thick. Install above the cooktop with a clearance