Installation requirements
of not less than 1/4" between the hood and the underside of the combustible
material or metal cabinet. The hood must be at least as wide as the appliance
and centered over the appliance. Clearance between the cooking surface and the
ventilation hood surface must never be less than 24 inches.
Exception : Installation of a listed microwave oven or cooking appliance over the
cooktop shall conform to the installations packed with that appliance.
30-in (76.2-cm) minimum clearance between the top of the cooking surface
and the bottom of an unprotected wood or metal cabinet; or If no 30-in
(76.2-cm) minimum clearance, 24-in (61-cm) minimum when the bottom of
the wood or metal cabinet is protected by not less than 0.25-in (0.64-cm)
flame-retardant millboard covered with not less than no. 28 MSG sheet steel,
0.015-in (0.038-cm) stainless steel, 0.024-in (0.061-cm) aluminum, or 0.020-in
(0.051-cm) copper.
18-in (45.7-cm) minimum between the countertop and the adjacent cabinet
bottom.
Recommended locations for gas piping and electrical outlets
17 in x 9 in
(43.2 cm x 22.9 cm)
Gas Wall Area
Recommended area
for through-the-wall
and through-the-floor
connection of gas pipe
stub and shut-off valve.
14 English
Recommended
position
12 in
(30.5 cm)
Recommended area
for 120 V electrical
outlet on rear wall

Gas requirements

Provide adequate gas supply
This range is designed to operate at a pressure of 5 in (13 cm) of water column on
natural gas or 10 in (25 cm) of water column on LP gas (propane or butane).
Make sure you are supplying your range with the type of gas for which it is
designed. Do not attempt to convert the appliance from the gas specified in this
manual to a different gas without consulting the gas supplier.
This range is convertible for use on natural or propane gas. If you decide to use
this range on LP gas, conversion must be made by a qualified LP installer before
attempting to operate the range.
For proper operation, the pressure of natural gas supplied to the regulator must be
between 5 in and 13 in (13 cm and 33 cm) of water column.
For LP gas, the pressure supplied must be between 10 in and 13 in (25 cm and
33 cm) of water column.
When checking for proper operation of the regulator, the inlet pressure must be at
least 1 in (2.5 cm) greater than the operating (manifold) pressure as given.
The pressure regulator located at the inlet of the range manifold must remain in
the supply line regardless of whether natural or LP gas is being used.
A flexible-metal appliance connector used to connect the range to the gas supply
line should have an I.D. of 0.5 in (1.3 cm) and be 5 ft (152 cm) in length for ease of
installation. In Canada, flexible connectors must be single-wall metal connectors no
longer than 6 ft (183 cm) in length.
Do not kink or damage the flexible metal tubing when moving the range.