Mitsubishi Electric EHPT17X-VM2D Service Manual page 86

Cylinder unit
Hide thumbs Also See for EHPT17X-VM2D:
Table of Contents

Advertisement

DISASSEMBLY PROCEDURE
16. How to remove the drain cock (primary circuit)
(1) Remove the front panel. (Refer to Procedure 1.)
<Pump valve side>
(2) Remove the drain cock from the pump valve by turning
the drain cock. (Photo 16-1)
<Pipe side (for P-HEX)>
(2) Remove the drain cock from the pipe by turning the drain
cock. (Photo 16-1)
<Pipe side (Only EHPT20X series)>
(2) Remove the drain cock from the pipe by turning the drain
cock. (Photo 16-2)
17. How to remove the drain cock (sanitary circuit)
(1) Remove the front panel. (Refer to Procedure 1.)
<DHW tank side>
(2) Remove the drain cock by detaching the quick connection.
(Photo 17-1)
• When reinstalling the quick connection, use a new
O-ring.
• Refer to Procedure 25 for how to attach and detach
the quick connection.
<P-HEX (Water-Water) side>
(2) Remove the drain cock from the P-HEX (Water-Water) by
turning the drain cock. (Photo 17-2)
Photo 17-2
P-HEX
OCH714D
Photo 16-1
Drain cock
(Pump valve side)
Photo 16-2
Photo 17-1
Quick
connection
O-ring
Drain cock
(P-HEX side)
85
PHOTOS/FIGURES
Drain cock
(Pipe side)
Drain cock (DHW tank side)
Drain cock for P-HEX
(Pipe side)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehpt17x-vm6dEhpt17x-ym9dEhpt20x-medEhpt20x-mhedwEhpt20x-tm9dEhpt20x-vm6d ... Show all