5. Alignment and Adjustments

1. High voltage is present at the high voltage terminals during any cook cycle.
2. It is neither necessary nor advisable to attempt measurement of the high voltage.
3. Before touching any oven components or wiring, always unplug the oven from its power source and
discharge the high voltage capacitor.
5-1 High Voltage Transformer
1. Remove connectors from the transformer terminals
and check continuity.
2. Normal resistance readings are as follows:
Secondary
Approx. 100
Filament
Approx. 0
Primary
Approx. 1.450
(Room temperature = 20° C)
5-2 Low Voltage Transformer
1. The low voltage transformer is located on the
Assy base plate.
2. Remove the low voltage transformer from the
Assy base plate and check continuity.
3. Normal resistor reading is shown in the table.
5-3 Magnetron
1. Continuity checks can indicate only an open
filament or a shorted magnetron. To diagnose an
open filament or shorted magnetron :
2. Isolate the magnetron from the circuit by
disconnecting its leads.
3. A continuity check across the magnetron filament
terminals should indicate one ohm or less.
4. A continuity check between each filament terminal
and magnetron case should read open.
PRECAUTION
Filament Terminals
Primary
Terminals
Gasket Plate
Cooling Fins
Secondary
Terminal
Terminals
Resistance
290
1~2(Input)
3~4(Output)
4.0
5~6(Output)
1.0
Magnetron Antenna
.
..
.