Performance Data Sheet - LG LSC23954 Series Owner's Manual

Side by side refrigerator
Hide thumbs Also See for LSC23954 Series:
Table of Contents

Advertisement

This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed
below. The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42.
System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of
Chlorine Taste and Odor and Nominal Particulate Class III.
*
Capacity: 500 gal (1,892 L)
Substance
Nominal Particulate
Class I Particle size:
0.5 to
1 um
Chlorine taste and odor
Class III
Note that while the testing was performed under standard laboratory conditions, actual performance may vary.
Application Guidelines / Water Supply Parameters
Service flow
0.5 gpm (1.89 lpm)
Water pressure
20 - 125 psi (138 - 862 kPa)
Water temperature 33ºF - 100ºF (0.6ºC - 38ºC)
WARNING
To reduce the risk associated with ingestion of
contaminants due to use with water that is
microbiologically unsafe or of unknown quality.
Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection
before or after the system.
Systems must be installed and operated in accordance
with manufacturer's recommended procedures and
guidelines

Performance Data Sheet

Models Number 5231JA2002A-S
Use with replacement cartridge 5231JA2002A
Influent Challenge
Average
Concentration.
Influent
Units apply to
Concentration
each row
At least 10,000
24,333
particles/ml
2.0 mg/L ± 10%
1.9
FILTER
Avg. Product
Water
Concentration
915
0.07
To reduce the risk of property damage due to water
leakage:
• Read and follow Use instructions before installation
and use of this system.
• Install on COLD water lines only.
• Comply with all state and local plumbing codes.
• Install a pressure limiting device and water
hammer arrester for inlet water pressures
exceeding 80 psi (552 kPa). Refer to Uniform
Plumbing Code, Sections 608.2 and 609.10.
• Never install or operate where inlet water pressure
may exceed 120 psi (827 kPa).
• Protect filter from freezing. Remove filter in
temperatures below 33° F (0.6° C).
• Replace cartridge at specified service interval.
Cartridge MUST be replaced at least every 6
months.
To purchase or replace water filters call your Service
Center. Refer to the Warranty Card to obtain the
telephone number of the Service Center near you and
ask for part no. 5231JA2002A or ADQ72910901.
25
NSF % reduction req.
Average
or Max. permissible
%
product water
Reduction
concentration
96
85%
96.4
50%
CAUTION