Pulsar HPSB 20A12C Manual

Hpsb 13,8v/20a/17ah buffer switch power supply unit

Advertisement

Quick Links

HPSB 20A12C
v.1.0
HPSB 13,8V/20A/17Ah
Buffer switch power supply unit.
EN**
Edition: 2 from 24.10.2016
Supercedes the edition: 1 from 04.03.2016

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HPSB 20A12C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pulsar HPSB 20A12C

  • Page 1 HPSB 20A12C v.1.0 HPSB 13,8V/20A/17Ah Buffer switch power supply unit. EN** Edition: 2 from 24.10.2016 Supercedes the edition: 1 from 04.03.2016...
  • Page 2 GREEN POWER www.pulsar.pl HPSB20A12C Features:   DC 13,8V/20A uninterruptible power supply* battery output full protection against short-circuit  and reverse polarity connection fitting battery: 17Ah/12V   wide range of mains supply: 176÷264V LED indication   protections: built-in power factor correction system (PFC) ...
  • Page 3 GREEN POWER www.pulsar.pl HPSB20A12C Fig.1. The block diagram of the PSU. 1.3 Description of PSU components and connectors. Table 1. Elements of the PSU. Element no. Description [Fig. 2] PSU module Connectors PSU: L-N power supply connector 230V AC, Protection connector PE...
  • Page 4 GREEN POWER www.pulsar.pl HPSB20A12C Fig.2. The view of the PSU.
  • Page 5 GREEN POWER www.pulsar.pl HPSB20A12C 1.4 Specifications: - electrical parameters (tab.2) - mechanical parameters (tab.3) - operation safety (tab.4) - operating parameters (tab.5) Table 2. Electrical parameters. PSU type A (EPS - External Power Source) 176÷264V AC 50Hz Mains supply Current up to 1,5A@230VAC max.
  • Page 6 GREEN POWER www.pulsar.pl HPSB20A12C Table 4. Operation safety Protection class PN-EN 60950-1:2007 I (first) Protection grade PN-EN 60529: 2002 (U) IP20 Electrical strength of insulation: - between input and output circuits of the PSU (I/P-O/P) 3000 V/AC min. - between input circuit and PE protection circuit (I/P-FG) 1500 V/AC min.
  • Page 7 GREEN POWER www.pulsar.pl HPSB20A12C 2.2 Installation procedure. 1. Before installation, cut off the voltage in the 230V power-supply circuit. 2. Mount the PSU in a selected location and connect the wires. 3. Connect the power cables (~230Vac) to L-N clips of the PSU. Connect the ground wire to the clip marked by the earth symbol PE (PSU module connector).
  • Page 8 CAUTION! The power supply unit is adapted for cooperation with the sealed lead-acid batteries (SLA). After the operation period they must not be thrown but recycled according to the applicable law. Pulsar Siedlec 150, 32-744 Łapczyca, Poland Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 E-mail: biuro@pulsar.pl, sales@pulsar.pl http:// www.pulsar.pl, www.zasilacze.pl...

Table of Contents