Mitsubishi Electric PKFY-P32VHM-ER2 Technical & Service Manual page 17

Table of Contents

Advertisement

PKFY-P32VHM-ER2
SYMBOL
I.B
INDOOR CONTROLLER BOARD
CONNECTOR
CN32
CN51
CN52
CN100
BZ1
BUZZER
FUSE FUSE (T3.15AL 250V)
LED1 POWER SUPPLY (I.B)
LED2
POWER SUPPLY (I.B)
SW2
SWITCH
SW3
SW4
SWE
X1
AUX.RELAY
LEV
LINEAR EXPANSION VALVE
MF
FAN MOTOR
MV
VANE MOTOR
TB2
TERMINAL
TB5
BLOCK
TB15
MF
DP
MS
M
3~
1~
1
FUSE
CNP
(BLU)
1
3
6
1
3
FAN
CNMF
X1
(WHT)
M-NET
SW2
CN2M (BLU)
ON
OFF
1
2
1 2 3 4 5 6
See fig: *1
*2
IT terminal
PAC-IT51AD-E
1
5
8
5 4
1
CN100 (WHT)
1
5
3
CN51 (WHT)
NOTES:
1. At servicing for outdoor unit,always follow the wiring diagram
of outdoor unit.
2. In case of using MA-Remote controller, please connect to TB15.
(Remote controller wire is non-polar.)
3. In case of using M-NET, please connect to TB5.
(Transmission line is non-polar.)
4. Symbol [S] of TB5 is the shield wire connection.
5. Symbols used in wiring diagram above are,
block,
:connecter.
6. The setting of the SW2 dip switches differs in the capacity.
For the detail, refer to the fig: *1.
OCH442B
PKFY-P40VHM-ER2
NAME
REMOTE SWITCH
CENTRALLY CONTROL
REMOTE INDICATION
IT TERMINAL
CAPACITY CODE
MODE SELECTION
MODEL SELECTOR
DRAIN PUMP (TEST MODE)
DRAIN PUMP (OPTION)
POWER SUPPLY
TRANSMISSION
MA-REMOTE CONTROLLER
POWER SUPPLY
~/N220-240V 50Hz
TB2
220V 60Hz
RED
FUSE
BREAKER
L
PULL
( 16A )
( 16A )
BLU
BOX
N
GRN/YLW
TO NEXT
INDOOR
UNIT
MV
M
CND
3
1
(BLK)
LDSWE(A)
5
(BLU)
5
1
6
1
VANE
CNRU
CN151
(WHT)
(WHT)
BZ1
8
LED1
SWE
CN100
*2
(WHT)
OFF
ON
ADDRESS
CN81
J41
(RED)
8
Pair
No.
J42
MA-REMOCON
CN3A
SW4
SW3
(BLU)
1
1 2 3 4
1 2 3 4 5 6 7 8
3
TB15
IT terminal
PAC-IT52AD-E
1
5
TB5 (SHIELD)
8
5 4
1
In connecting optional IT terminal,
CN100 (WHT)
use either CN51 or CN52 which is
1
5
not connected.
CN52 (WHT)
Be careful for connector colors.
: terminal
PKFY-P50VHM-ER2
SYMBOL
NAME
TH21
THERMISTOR ROOM TEMP. DETECTION
(0°C/15kΩ, 25°C/5.4kΩ)
TH22
PIPE TEMP. DETECTION / LIQUID
(0°C/15kΩ, 25°C/5.4kΩ)
TH23
PIPE TEMP. DETECTION / GAS1
(0°C/15kΩ, 25°C/5.4kΩ)
TH24
PIPE TEMP. DETECTION / GAS2
(0°C/15kΩ, 25°C/5.4kΩ)
ADDRESS BOARD
A.B
SWA
SWITCH
FAN SPEED SELECTOR
SW1
MODE SELECTION
SW11
ADDRESS SETTING 1s DIGIT
SW12
ADDRESS SETTING 10ths DIGIT
SW14
BRANCH No.
S.B
SWITCH BOARD
SWE1
EMERGENCY OPERATION (HEAT)
SWE2
EMERGENCY OPERATION (COOL)
W.B
PCB FOR WIRELESS REMOTE CONTROLLER
LED1
LED (OPERATION INDICATOR: GREEN)
LED2
LED (PREPARATION FOR HEATING: ORANGE)
RU
RECEIVING UNIT
DRAIN PUMP (OPTION)
DP
FS
DRAIN FLOAT SWITCH (OPTION)
3
6
LEV
M
I.B
CN52
W.B
*2
(GRN)
5
1
When attaching drain
pump(option), remove
1
5
CN51
the jumper connector
*2
(WHT)
CN4F and fit the drain
CN24
6
1
LEV
float switch (FS).
(YLW)
CN60
2 1
(YLW)
FLOAT SW
CN4F
(WHT)
1
4
1
GAS2
CN2G
(BLK)
2 1
CN32
(WHT)
LIQUID/GAS1
CN44
3
1
(WHT)
ADDRESS
4
1
CN42
(RED)
1
4
1
INTAKE
CN20
(RED)
2 1
LED2
4
8
TO MA-REMOTE
1
CONTROLLER
2
DC8.7-13V
ON
M1
TO OUTDOOR UNIT
OFF
BC CONTROLLER
M2
1
2
3
REMOTE CONTROLLER
DC24-30V
S
A.B
LED on indoor board for service
Mark
Meaning
Main power supply
LED1
Power supply for
LED2
MA-Remote controller
17
17
LD SWE(B)
LED2
LD101(B)
SWE1
SWE2
RU
LED1
S.B
When attaching drain pump
(option)
FS
FLOAT SW
CN4F
(WHT)
4
1
The black square (
)
indicates a switch
TH24
position. <
*1>
Models
SW2
TH23
ON
TH22
P32
OFF
123456
ON
TH21
P40
OFF
123456
ON
P50
OFF
123456
ADDRESS
CN43
(RED)
SW1
3
2
ADDRESS
1
CN82
4 5 6 7 8 9 10
SWA
(RED)
SW12
SW11
SW14
10ths
1s
BRANCH
DIGIT
DIGIT
No.
Main power supply (Indoor unit:220-240V)
Power on → Iamp is lit
Power supply for MA-Remote controller
on → Iamp is lit
Function