Advertisement

Quick Links

AIR CONDITIONER
Owner's Manual
Original Instructions
Split Air Conditioner
Thank you for choosing our product.
Please read this Owner's Manual carefully before operation and
retain it for future reference.
If you have lost the Owner's Manual, please contact the local
agent or visit www.gree.com or send an email to
global@gree.com.cn for the electronic version.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MTS2R-18HDI and is the answer not in the manual?

Questions and answers

Summary of Contents for Tosot MTS2R-18HDI

  • Page 1 AIR CONDITIONER Owner's Manual Original Instructions Split Air Conditioner Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact the local agent or visit www.gree.com or send an email to global@gree.com.cn for the electronic version.
  • Page 3 MTS2R-18HDI MTS4R-28HDI...
  • Page 4: Table Of Contents

    In line with the company’s policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice. CONTENTS GENERAL INFORMATION Conformity And Range The Refrigerant Warning The Instructions Before Use Name of Parts Technical Data Outdoor Unit Working Temperature Range...
  • Page 5: Conformity And Range

    EXPLANATION OF SYMBOLS GENERAL INFORMATION Indicates a hazardous situation that, if not avoided, will DANGER result in death or serious injury. Indicates a hazardous situation that, if not avoided, could WARNING result in death or serious injury. Indicates a hazardous situation that, if not avoided, may CAUTION result in minor or moderate injury.
  • Page 6: The Refrigerant

    THE REFRIGERANT GENERAL INFORMATION Please read this operating manual carefully before operating the unit. to the material objects for reference. The Refrigerant ● To realize the function of the air conditioner unit, a special refrigerant circulates leads to explosion . It can ●...
  • Page 7: Warning

    GENERAL INFORMATION Warning Operation and Maintenance This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory ormental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 8 GENERAL INFORMATION Warning If the air conditioner operates under abnormal conditions, it may cause malfunction,electric shock or fire hazard. When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other than metal. Do not step on top panel of outdoor unit, or put heavy objects.
  • Page 9 GENERAL INFORMATION Warning The air conditioner is the first class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
  • Page 10: The Instructions Before Use

    THE INSTRUCTIONS BEFORE USE GENERAL INFORMATION WARNING When having a burning smell or The power supply must adopt the Never cut off or damage power ★ ★ ★ smoke,please turn off the power special circuit that with air switch cables and control wires. If the supply and contact with the ser- protection and assure it has enou- power cable and signal control...
  • Page 11: Name Of Parts

    NAME OF PARTS GENERAL INFORMATION MTS2R-18HDI、21K: Warning Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen. Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case.
  • Page 12 NAME OF PARTS GENERAL INFORMATION 14K : Warning Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen. Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case.
  • Page 13: Technical Data

    TECHNICAL DATA GENERAL INFORMATION MTS2R-18HDI MODE Electrical data Electricity supply 220-240V~,50Hz 220-240V~,50Hz 220-240V~,50Hz Fuse or air switch Minimum power cord section Size and clearance TECHNICAL DATA GENERAL INFORMATION MODE 24K 、MTS4R-28HDI Electrical data Electricity supply 220-240V~,50Hz Fuse or air switch...
  • Page 14: Electrical Connections

    ELECTRICAL CONNECTIONS INSTALLER 14K: 1. Remove the handle at the right side plate of the An all-pole disconnection switch having a contact outdoor unit (one screw). separation of at least 3mm in all pole should be connected in fixed wiring. 2.
  • Page 15 INSTALLER ELECTRICAL CONNECTIONS 、21K 、24K Remove the handle at the right side plate of the outdoor MTS2R-18HDI unit (one screw). Handle 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection.
  • Page 16 ELECTRICAL CONNECTIONS INSTALLER MTS4R-28HDI、36K : 1. Remove the handle at the right side plate of the An all-pole disconnection switch having a contact outdoor unit (one screw). separation of at least 3mm in all pole should be connected in fixed wiring. 2.
  • Page 17 ELECTRICAL CONNECTIONS INSTALLER 42K : 1. Remove the handle at the right side plate of the An all-pole disconnection switch having a contact outdoor unit (one screw). separation of at least 3mm in all pole should be connected in fixed wiring. 2.
  • Page 18: Installing The Outdoor Unit

    INSTALLING THE OUTDOOR UNIT INSTALLER Location Install the drain fitting and the drain hose (for model with heat pump only) Use bolts to secure the unit to a flat, solid floor. Condensation is produced and flows from the out- When mounting the unit on a wall or the roof, make door unit when the appliance is operating in the sure the support is firmly secured so that it cannot heating mode.
  • Page 19: Maintenance

    Contact service center before installation to avoid the malfunction due to unprofessional installation. When picking up and moving the units, you must be guidedby trained and qualified person. Ensure that the recommende dspace is left around the appliance. MTS4R-28HDI MTS2R-18HDI 50cm or more Space to the cover...
  • Page 20: Check After Installation

    CHECK AFTER INSTALLATION INSTALLER Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises May cause unsatisfactory cooling (heating) Has the gas leakage been checked? effect Is the thermal insulation of the unit May cause condensation and water dropping sufficient? Is the drainage smooth?
  • Page 21: Safety Operation Of Flammable Refrigerant

    SAFETY OPERATION OF FLAMMABLE REFRIGERANT INSTALLER Qualification requirement for installation and maintenance man All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using the flammable refrigerant.
  • Page 24 GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai,Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn www.gree.com 66129930487...

This manual is also suitable for:

Mts4r-28hdi

Table of Contents