Table of Contents

Advertisement

Available languages

Available languages

Quick Links

SH - NLFREN - v1.1 - 01122016
P.02 Gelieve te lezen en voor later gebruik bewaren
NL
P.09 Veuillez lire et conserver pour consultation ultérieure
FR
P.16 Please read and keep for future reference
EN
SH125/250
HANDLEIDING - MODE D'EMPLOI - MANUAL
SH125/250 (758613080)
SH200/400 (758612040)
SH300/600-18 (758613070)
SH500/1000 (758611012)
Elektrische takel
Treuil électrique
Electric hoist
TOOLS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SH125/250 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MW TOOLS SH125/250

  • Page 1 SH - NLFREN - v1.1 - 01122016 TOOLS SH125/250 HANDLEIDING - MODE D’EMPLOI - MANUAL SH125/250 (758613080) SH200/400 (758612040) SH300/600-18 (758613070) SH500/1000 (758611012) Elektrische takel Treuil électrique Electric hoist P.02 Gelieve te lezen en voor later gebruik bewaren P.09 Veuillez lire et conserver pour consultation ultérieure...
  • Page 2: Table Of Contents

    SH - NLFREN - v1.1 - 01122016 TOOLS Inhoud 1 Veiligheid ................................2 2 Technische specificaties ............................3 3 Omschrijving ................................. 3 4 Toepassingsgebied ..............................4 5 Voorbereiding ................................ 4 6 Installatie................................4 7 Gebruik ................................5 8 Onderhoud en reiniging ............................7 9 Storingen ................................
  • Page 3: Technische Specificaties

    SH - NLFREN - v1.1 - 01122016 TOOLS 2 Technische specificaties Model SH125/250 SH200/400 SH300/600-18 SH500/1000 Nominale spanning 230 V 230 V 230 V 230 V Nominale frequentie 50 Hz 50 Hz 50 Hz 50 Hz Nominaal vermogen 1050 W...
  • Page 4: Toepassingsgebied

    level (LWA) SH - NLFREN - v1.1 - 01122016 • The LWA values stated here only indicate the loudness emitted this machine. Whether TOOLS required to wear hearing protection can’t determined here. This depends how mu reaches ear of operator. this, among other things,...
  • Page 5: Gebruik

    additional load hook with deviating shaft. The electric pulley will be attached at the top. Attach the pulley with bearer frame on the The electric pulley will be attached at the top. Attach the pulley with bearer frame on the crossbar.
  • Page 6 SH - NLFREN - v1.1 - 01122016 TOOLS 5. Als de takel de last niet onmiddellijk kan hijsen, stop deze onmiddellijk, om een ongeval te voorkomen. 6. Maak zeker dat de last stevig aan de haak bevestigd is. Houd de grootst mogelijke afstand tussen de last en de kabel tijdens het optillen.
  • Page 7: Onderhoud En Reiniging

    SH - NLFREN - v1.1 - 01122016 TOOLS 8 Onderhoud en reiniging • Trek de stekker voor het onderhoud of de reiniging van de takel. Maintenance and Cleaning • Maak de takel schoon met een vochtig doek met vloeibare zeep. Gebruik geen oplosmiddel, dat de kunststof onderdelen Disconnect the power plug prior to performing any...
  • Page 8: Storingen

    SH - NLFREN - v1.1 - 01122016 TOOLS 9 Storingen Storingen Oorzaken Oplossingen De On/Off schakelaar wordt bediend, Het toestel is niet aangesloten Sluit het toestel aan maar de motor start niet op De elektrische kabels zijn beschadigd Controleer en sluit de kabels aan Schakelaar defect Repareer of vervang de schakelaar De condensator is doorgebrand...
  • Page 9: Sécurité

    SH - NLFREN - v1.1 - 01122016 TOOLS Table des matières 1 Sécurité ................................. 9 2 Spécifications techniques ............................10 3 Description ................................10 4 Champs d’application ............................11 5 Préparation ................................. 11 6 Installation ................................11 7 Utilisation ................................12 8 Entretien et nettoyage ............................
  • Page 10: Spécifications Techniques

    SH - NLFREN - v1.1 - 01122016 TOOLS 2 Spécifications techniques Modèle SH125/250 SH200/400 SH300/600-18 SH500/1000 Tension nominale 230 V 230 V 230 V 230 V Fréquence nominale 50 Hz 50 Hz 50 Hz 50 Hz Puissance nominale 500 W...
  • Page 11: Champs D'application

    dB(A) dB(A) dB(A) level (LWA) SH - NLFREN - v1.1 - 01122016 • The LWA values stated here only indicate the loudness emitted this machine. Whether TOOLS required to wear hearing protection can’t determined here. This depends how mu reaches ear of operator.
  • Page 12: Utilisation

    Insert the load hook into the hook bracket the mounting casing when using additional load hook with deviating shaft. additional load hook with deviating shaft. The electric pulley will be attached at the top. Attach the pulley with bearer frame on the SH - NLFREN - v1.1 - 01122016 The electric pulley will be attached at the top.
  • Page 13 SH - NLFREN - v1.1 - 01122016 TOOLS 5. Si le treuil ne peut pas soulever une charge immédiatement, arrêtez-le immédiatement, pour éviter tout accident. 6. Assurez-vous que la charge est bien fixée au crochet. Maintenez le plus de distance possible entre la charge et le câble en acier pendant le travail.
  • Page 14: Entretien Et Nettoyage

    SH - NLFREN - v1.1 - 01122016 TOOLS 8 Entretien et nettoyage Maintenance and Cleaning • Débranchez le câble d’alimentation avant de travailler sur le treuil. • Nettoyez le treuil avec un chiffon humide imprégné de savon liquide. N’utilisez pas de solvant, qui pourrait endommager Disconnect the power plug prior to performing any...
  • Page 15: Résolution De Problèmes

    SH - NLFREN - v1.1 - 01122016 TOOLS 9 Résolution de problèmes Pannes Causes Solutions L’interrupteur On/Off est actionné mais L’appareil n’est pas branché Branchez l’appareil le moteur de démarre pas Les câbles électriques sont endommagés Vérifiez les câbles et rebranchez-les Interrupteur défectueux Réparez ou remplacez l’interrupteur Le condensateur est grillé...
  • Page 16: Safety

    SH - NLFREN - v1.1 - 01122016 TOOLS Contents 1 Safety .................................16 2 Technical specifications ............................17 3 Description ................................17 4 Area of application ..............................18 5 Preparation .................................18 6 Installation ................................18 7 Operation ................................19 8 Maintenance and cleaning ............................21 9 Troubleshooting ..............................22 10 Spare parts ...............................
  • Page 17: Technical Specifications

    SH - NLFREN - v1.1 - 01122016 TOOLS 2 Technical specifications Model SH125/250 SH200/400 SH300/600-18 SH500/1000 Rated voltage 230 V 230 V 230 V 230 V Rated frequency 50 Hz 50 Hz 50 Hz 50 Hz Power rating 500 W...
  • Page 18: Area Of Application

    level (LWA) SH - NLFREN - v1.1 - 01122016 • The LWA values stated here only indicate the loudness emitted this machine. Whether TOOLS required to wear hearing protection can’t determined here. This depends how mu reaches ear of operator. this, among other things,...
  • Page 19: Operation

    additional load hook with deviating shaft. additional load hook with deviating shaft. The electric pulley will be attached at the top. Attach the pulley with bearer frame on the SH - NLFREN - v1.1 - 01122016 The electric pulley will be attached at the top. Attach the pulley with bearer frame on the crossbar.
  • Page 20 SH - NLFREN - v1.1 - 01122016 TOOLS 5. If the cable winch cannot hoist a load immediately, switch it off immediately to prevent damages and accidents. 6. Please be sure that the load is securely fastened to the load hook. Maintain the largest possible distance to the load and steel cable during operation.
  • Page 21: Maintenance And Cleaning

    SH - NLFREN - v1.1 - 01122016 TOOLS 8 Maintenance and cleaning Maintenance and Cleaning • Disconnect the power plug prior to performing any work on the device. Disconnect the power plug prior to performing any work on the device. •...
  • Page 22: Troubleshooting

    SH - NLFREN - v1.1 - 01122016 TOOLS 9 Troubleshooting Common malfunctions Causes Solutions The Off/On switch is used but the motor It is not plugged into the power supply Connect the item to the power supply does not turn The wires are broken or ripped Check the wires and plug it in again to the outlet...
  • Page 23: Onderdelen

    SH - NLFREN - v1.1 - 01122016 TOOLS 10 Onderdelen 10 Pièces détachées 10 Spare parts SH125/250...
  • Page 24 SH - NLFREN - v1.1 - 01122016 TOOLS SH125/250 Parts List Material Material Outer hex bolt M8x25-8.8级 spring washer 65Mn φ8x2 washer Q235 φ8x1.6 Fasten clamp Q235 Socket sunk head screw M8x18-8.8级 subulate tooth-washer 65Mn φ8 Housing cover Sleeve for housing cover...
  • Page 25 SH - NLFREN - v1.1 - 01122016 TOOLS ADC12 back housing cover fan cover M5x148 Outer hex bolt Cross pan head screw M4x6 lower airproof loop of junction box lower cover of junction box flat washer Q235 φ4 Cross pan head screw M4X12 Cross pan head tapping screw M3x14...
  • Page 26 SH - NLFREN - v1.1 - 01122016 TOOLS capacitor AC450V 15UF/6UF airproof loop of controlling handle lower cover of controlling handle plug-in Reed plug-in Reed Jacket cable line 4x1.0mm H07RN-F binding reed of position limited switch 65Mn tie-in of position limited switch Cross pan head screw M4X6 socket screw...
  • Page 27 SH - NLFREN - v1.1 - 01122016 TOOLS SH200/400 - SH300/600-18...
  • Page 28 SH - NLFREN - v1.1 - 01122016 TOOLS SH200/400 - SH300/600-18 Parts List Material Description Outer hex bolt M10x25-8.8 spring washer 65Mn φ10x2.5 washer Q235 φ10x1.6 Fasten clamp Q235 pulley hook Socket sunk head screw M10x25-8.8 65Mn subulate tooth-washer φ10 Housing cover rolling bearing6203 6203...
  • Page 29 SH - NLFREN - v1.1 - 01122016 TOOLS Outer hex bolt M5x175 Cross pan head screw M4x6 lower airproof loop of junction box lower cover of junction box flat washer Q235 φ4 Cross pan head screw M4X12 Cross pan head tapping screw M3x14 position limited switch 65Mn...
  • Page 30 SH - NLFREN - v1.1 - 01122016 TOOLS 65Mn reed of position limited switch tie-in of position limited switch M4X6 Cross pan head screw M8x40-8.8 socket screw position limited bracket down limited position pole Q235 limited position slice Q235 65Mn up reed of position limited switch limited position slice Q235...
  • Page 31 SH - NLFREN - v1.1 - 01122016 TOOLS SH500/1000...
  • Page 32 SH - NLFREN - v1.1 - 01122016 TOOLS SH500/1000 Parts List Material Description Outer hex bolt M12x30 washer Q235 φ12 65Mn spring washer φ12 Fasten clamp 6.0mm Q235 Pulley hook Outer hex bolt M10x25 65Mn spring washer φ10 washer Q235 φ10 Housing cover rolling bearing6204...
  • Page 33 SH - NLFREN - v1.1 - 01122016 TOOLS back housing cover ZL102 fan cover Outer hex bolt M6x210 Cross pan head screw M4x6 lower airproof loop of junction box lower cover of junction box Q235 flat washer φ4 Cross pan head screw M4x12 position limited switch JDLA-106, AC-15, 8A, AC 250V...
  • Page 34 SH - NLFREN - v1.1 - 01122016 TOOLS guiding line 1.0mm2 cooper connection ending Anti-kink device of cable line tooth washer 65Mn φ4 Terminal piece φ4x0.5 copper waterproof plug and cable line 3G1.0mm²x0.65m H05RN-F cable line 5x1.0mm H07RN-F plug-in Reed 铜...
  • Page 35: Eg Conformiteitsverklaring

    Déclare par la présente que le produit suivant : Hereby declares that the following product : Product Elektrische takel Produit Treuil électrique Product Electric hoist SH125/250 (758611250) Order nr. : SH200/400 (758612040) SH300/600-18 (758613070) SH500/1000 (758611012) Geldende CE-richtlijnen 2006/42/EC Normes CE en vigueur...

Table of Contents