INSTALLATION DIAGRAM OF INDOOR UNIT
INSTALLATION DIAGRAM OF INDOOR UNIT
3
Batteries
6
Flat head
wood screw
2
Wireless remote control
Optional Installation Parts
Part
Parts name
code
Refrigerant piping
Liquid side
: Ø6.35 mm
Gas side
: Ø9.52 mm
A
(RAS-M10, 13PKVPG-E)
: Ø12.7 mm
(RAS-M16PKVPG-E)
Pipe insulating material
B
(polyethylene foam, 6 mm thick)
Putty, PVC tapes
C
Refrigerant piping
must be protected from
physical damage.
Install a plastic cover or
equivalent.
4
Remote control
holder
Vinyl tape
Apply after carrying
out a drainage test.
Q'ty
One
each
One
each
Hook
1
Installation
plate
Bush body
1
6
For the rear left and left piping
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit for
better operation.
The auxiliary piping can be connected to
the left, rear left, rear right, right, bottom
right or bottom left.
Shield pipe
Right
Rear
right
Bottom
right
Do not allow the drain hose to get slack.
Make sure to run the drain hose sloped
downward.
The fl are connection should be installed
outdoors.
Insulate the refrigerant pipes separately
with insulation, not together.
6 mm thick heat resisting
polyethylene foam
Wall
Left
Rear
left
Bottom left
Cut the piping
hole sloped
slightly.