Sharp MD-R2H Service Manual page 20

Table of Contents

Advertisement

MD-R2H
e) TEMP setting
Step No.
Setting Method
Step 1
Testmode STOP state
Step 2
Press the ENTER button seven times.
Step 3
Press once the MD PLAY button. Focus setting menu
Step 4
Press the ENTER button four times.
Step 5
Press once the MD PLAY button. TEMP reference value setting
Step No.
Setting Method
Step 1
EJECT state (or mechanism-less state)
Step 2
Press the DELETE/CLEAR button. TEMP reference value setting
: Setting volue,
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
f) CONTROL setting
Setting Method
Step No.
Step 1
Testmode STOP state
Step 2
Press the ENTER button seven times.
Step 3
Press once the MD PLAY button. Focus setting menu
Step 4
Press the ENTER button five times.
Step 5
Press once the MD PLAY button. CONTROL 1 setting
Step 6
Press once the ENTER button.
Step 7
Press once the ENTER button.
Step 8
Press once the ENTER button.
Step 9
Press once the ENTER button.
Step 10
Press once the ENTER button.
Step 11
Press once the ENTER button.
Step 12
Press once the ENTER button.
Step 13
Press once the ENTER button.
Step 14
Press once the ENTER button.
Step 15
Press once the ENTER button.
Step 16
Press once the ENTER button.
Step 17
Press once the ENTER button.
Step 18
Press once the ENTER button.
Step 19
Press once the ENTER button.
Step 20
Press once the ENTER button.
Step No.
Setting Method
Step 1
EJECT state (or mechanism-less state)
Step 2
Press the NAME/TOC EDIT button. CONTROL 1 setting
Step 3
Press once the ENTER button.
: Setting volue
• When the jog key is turned upward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
• When the jog key is turned downward while the setting is displayed, the setting increases, and a new setting is stored in LSI.
• CONTROL 1
Pit 7
: High frequency superposition ON/OFF in record mode (0:OFF, 1:IN)
Pit 6~4
: Play start SD number (30 to 100 sector, 10 sector step)
Pit 2~0
: High speed jump over-run (384 to 830 lines, 64 lines step)
• CONTROL 2
Pit 4~0
: EEPROM version (a~)
EEPROM setting menu
TEMP setting menu
:
Measurement value
EEPROM setting menu
CONTROL setting menu
CONTROL 2 setting
Setting of spin kick level in MOVE state
Setting of readjustment interval time (minutes)
Setting of equalizer coefficients A and D (high reflection)
Setting of equalizer coefficients A and D (low reflection pit)
Setting of equalizer coefficients A and D (low reflection groove)
Setting of equalizer coefficients B and C (high reflection)
Setting of equalizer coefficients B and C (low reflection pit)
Setting of equalizer coefficients B and C (low reflection groove)
Setting of autolevel slicer gain (high reflection)
Setting of autolevel slicer gain (low reflection pit)
Setting of autolevel slicer gain (low reflection groove)
Setting of autolevel slicer offset (high reflection)
Setting of autolevel slicer offset (low reflection pit)
Setting of autolevel slicer offset (low reflection groove)
CONTROL 2 setting
Remarks
Remarks
Remarks
Remarks
– 20 –
Display
[ t s m
e
]
[E E P R O M _ S E T]
[ _ _ F o c u s _ _ _ ]
[ _ _ _ T e m p _ _ _ ]
[ T E M P _
_
]
Display
[ _ _ E J E C T _ _ _ ]
[ T E M P _
_
]
Display
[ t s m
e
]
[E E P R O M _ S E T]
[ _ _ F o c u s _ _ _ ]
[ _ C o n t r o l _ _ ]
[ C O N T R L 1_
]
[ C O N T R L 2_
]
[ S P K L E V m_
]
[ A D J T T M_ _
]
[ H D E Q A D_ _
]
[ L D E Q A D_ _
]
[ G D E Q A D_ _
]
[ H D E Q B C_ _
]
[ L D E Q B C_ _
]
[ G D E Q B C_ _
]
[ H A L S G_ _ _
]
[ L A L S G_ _ _
]
[ G A L S G_ _ _
]
[ H A L S O F_ _
]
[ L A L S O F S_
]
[ G A L S O F S_
]
Display
[ _ _ E J E C T _ _ _ ]
[ C O N T R L 1_
]
[ C O N T R L 1_
]

Advertisement

Table of Contents
loading