Page 1
PAN03 ; PAN10 Switch Module with meter Fig 1. PAN03 Assembling...
Page 2
Fig 2. PAN10 Assembling Auto Inclusion This plug-in ON/OFF switch PAN03/PAN10 is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus enabled devices displaying the Z- The function of auto inclusion will be executed as long as the switch does not have...
Page 3
Sometimes people are not easy to execute exclusion or inclusion especially when auto inclusion) PAN03 already installed in a wall box. To solve this issue, PAN03 support a special feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association”...
No node ID Under normal operation, when the Switch has not been allocated a 3. There are 3 mode PAN03/PAN10 can be configured to match different kind of node ID, the LED flashes on and off alternately at 2-second inter- wall switch, vals.
Page 5
one association group with one node support for Grouping 1. For group 1, the Switch Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)] will report its latest status to Z-Wave Controller. Binary Switch Get Command:[Command Class Switch Binary, Switch Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, Binary Get] ALARM_REPORT.
Page 6
Meter Value 4 = 0xEA (W) 2-1-3 Overload alarm report Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W When PAN03/PAN10 detects the current is more than 12A, it will send Alarm Report to Group 1 node. 2-2-2 Accumulated Power Consumption (KW/h)
Page 7
When receiving Meter Get Command, it will report Meter Report Command to the 2-2-3 Clearing accumulated power consumption node. Whenever re-start counting the accumulated power consumption is needed, you can use Meter Reset Command to clear it. Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)] Meter Report Command: Meter Reset Command: [Command Class Meter, Meter Reset] [Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type =...
Page 8
0 : Switch off 3-2 KWH Meter Report Period: Restore switch 1 : Last switch state If the setting is configured for 1hour (set value =6), the PAN03/PAN10 will report its state mode 2 : Switch on 0:Disable Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The...
Page 9
3-8 Auto off timer: 3-3 Threshold of current for Load Caution Whenever PAN03/PAN10 switches to on, the auto off timer begin to count down. This is a warning when the current of load over the preset threshold value, if the After the timer decrease to zero, it will switch to off automatically.
The Switch supports Command Classes including… 3-12-1 Disable : The function of Watt differential report will be disabled. * COMMAND_CLASS_ZWAVEPLUS_INFO 3-12-2 5% : When the differential value of Watt is over 5%, PAN03/PAN10 will send * COMMAND_CLASS_VERSION a meter report to the associated group.
Frequency Range PAN03-1: 868.40MHz; 869.85MHz(EU) / 4. After putting it into use, the body of Module will become a little bit hot of which PAN03-2: 908.40MHz; 916.00MHz(USA/Canada) / phenomenon is normal. PAN03-3: 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP)
Page 12
(2) This device must accept any interference received, including interference that may cause undesired operation. Company of License Holder:Philio Technology Corporation FCC Caution: Any changes or modifications not expressly approved by the party responsible Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New for compliance could void the user's authority to operate this equipment.