Summary of Contents for Philio PAN03

  • Page 1 PAN03 ; PAN10 Switch Module with meter Fig 1. PAN03 Assembling...
  • Page 2 Fig 2. PAN10 Assembling Auto Inclusion This plug-in ON/OFF switch PAN03/PAN10 is a security enabled wireless switch, based on Z-Wave Plus technology. Z-Wave Plus enabled devices displaying the Z- The function of auto inclusion will be executed as long as the switch does not have...
  • Page 3 Sometimes people are not easy to execute exclusion or inclusion especially when auto inclusion) PAN03 already installed in a wall box. To solve this issue, PAN03 support a special feature that can use S1 or S2 to execute “exclusion, inclusion, Reset or Association”...
  • Page 4: Led Indication

    No node ID Under normal operation, when the Switch has not been allocated a 3. There are 3 mode PAN03/PAN10 can be configured to match different kind of node ID, the LED flashes on and off alternately at 2-second inter- wall switch, vals.
  • Page 5 one association group with one node support for Grouping 1. For group 1, the Switch Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)] will report its latest status to Z-Wave Controller. Binary Switch Get Command:[Command Class Switch Binary, Switch Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT, Binary Get] ALARM_REPORT.
  • Page 6 Meter Value 4 = 0xEA (W) 2-1-3 Overload alarm report Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W When PAN03/PAN10 detects the current is more than 12A, it will send Alarm Report to Group 1 node. 2-2-2 Accumulated Power Consumption (KW/h)
  • Page 7 When receiving Meter Get Command, it will report Meter Report Command to the 2-2-3 Clearing accumulated power consumption node. Whenever re-start counting the accumulated power consumption is needed, you can use Meter Reset Command to clear it. Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)] Meter Report Command: Meter Reset Command: [Command Class Meter, Meter Reset] [Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type =...
  • Page 8 0 : Switch off 3-2 KWH Meter Report Period: Restore switch 1 : Last switch state If the setting is configured for 1hour (set value =6), the PAN03/PAN10 will report its state mode 2 : Switch on 0:Disable Accumulated Power Consumption (KW/h) every 1 hour to Group1 node. The...
  • Page 9 3-8 Auto off timer: 3-3 Threshold of current for Load Caution Whenever PAN03/PAN10 switches to on, the auto off timer begin to count down. This is a warning when the current of load over the preset threshold value, if the After the timer decrease to zero, it will switch to off automatically.
  • Page 10: Troubleshooting

    The Switch supports Command Classes including… 3-12-1 Disable : The function of Watt differential report will be disabled. * COMMAND_CLASS_ZWAVEPLUS_INFO 3-12-2 5% : When the differential value of Watt is over 5%, PAN03/PAN10 will send * COMMAND_CLASS_VERSION a meter report to the associated group.
  • Page 11: Specification

    Frequency Range PAN03-1: 868.40MHz; 869.85MHz(EU) / 4. After putting it into use, the body of Module will become a little bit hot of which PAN03-2: 908.40MHz; 916.00MHz(USA/Canada) / phenomenon is normal. PAN03-3: 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP)
  • Page 12 (2) This device must accept any interference received, including interference that may cause undesired operation. Company of License Holder:Philio Technology Corporation FCC Caution: Any changes or modifications not expressly approved by the party responsible Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New for compliance could void the user's authority to operate this equipment.