Indoor Unit - Panasonic CS-RE18QKE Service Manual

Hide thumbs Also See for CS-RE18QKE:
Table of Contents

Advertisement

11.2 Indoor Unit

11.2.1 How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent if from the vibration.
Wall
Measuring
Tape
RE9***,UE9***,YE9***
RE12***,UE12***,YE12***
RE18***,UE18***
The center of installation plate should be at more than  at right and left of the wall.
The distance from installation plate edge to ceiling should more than .
From installation plate center to unit's left side is .
From installation plate center to unit's right side is .
B
: For left side piping, piping connection for liquid should be about  from this line.
: For left side piping, piping connection for gas should be about  from this line.
1
Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
o Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a
level gauge.
2
Drill the piping plate hole with ø70 mm hole-core drill.
o Line according to the left and right side of the installation plate. The meeting point of the extended line is the
center of the hole. Another method is by putting measuring tape at position as shown in the diagram above.
The hole center is obtained by measuring the distance namely 128 mm for left and right hole respectively.
o Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side.
11.2.2
To Drill a Hole in the Wall and
Install a Sleeve of Piping
1
Insert the piping sleeve to the hole.
2
Fix the bushing to the sleeve.
3
Cut the sleeve until it extrudes about 15 mm
from the wall.
When the wall is hollow, please be sure to use
the sleeve for tube assembly to prevent dangers
caused by mice biting the connection cable.
4
Finish by sealing the sleeve with putty or
caulking compound at the final stage.
More than
2
241.5 mm
PIPE HOLE CENTER
DISTANCE
TO PIPE
HOLE
128 mm
CENTER
128 mm
Model
490 mm
RE15***
590 mm
RE24***
CAUTION
Wall
1
More
screw
than
2
128 mm
Installation plate
1
For best strength of
INDOOR unit installation,
it is highly recommended
to locate " " at 5
position as shown.
Dimension
82 mm
439 mm
82 mm
539 mm
Indoor
Sleeve
for tube
assembly
ø70 mm
through hole
28
More than 1
DISTANCE TO
PIPE HOLE
CENTER 128 mm
241.5 mm
PIPE HOLE
CENTER
128 mm
432 mm
43 mm
95 mm
532 mm
169 mm
219 mm
Wall
Outdoor
15 mm
Bushing for tube
assembly
Putty or caulking compound
Wall
Approx. 5 - 7 mm