Summary of Contents for Perlick PKD24B

  • Page 1 Owner’s Manual Keep with machine for reference PKD24B INSTALLATION & OPERATION Rev. 11.09 P e r l i c k C o r p o r a t i o n 8 3 0 0 W G o o d H o p e R d...
  • Page 2: Table Of Contents

    ABLE OF ONTENTS PKD24B 1. SPECIFICATIONS ..................2 1.1. PKD24B ................E RROR OOKMARK NOT DEFINED 1.2. PKD24B O ....................3 PERATIONAL YCLE 2. GETTING STARTED ..................5 2.1. PKD24B ....................5 NTRODUCTION TO THE 2.2....................6 ECEIVING AND NSTALLATION 2.2.1.
  • Page 3: Specifications

    0.8 kW (Not Booster Heater) WASH PUMP MOTOR 13.4 AMPS *MUST CONNECT TO DEDICATED 20 AMP SUPPLY CIRCUIT. COMPLIANCE WITH LOCAL ELECTRICAL CODES MUST BE FOLLOWED. SHIPPING WEIGHT PKD24B (Approximate) 190# 86.2 kg Page PKD24B INSTALLATION & OPERATION MANUAL Rev. 11.09...
  • Page 4: Pkd24B Operational Cycle

    1.2. PKD24B Operational Cycle The PKD24B Operational Cycle has a total cycle time of 2 minutes (120 seconds). The Timing Diagram and the steps listed below detail the individual functions that are executed during each Operational Cycle. Seconds: Instant Start Relay...
  • Page 5 7. Cam switch 8 operates the optional sustainer heater. This cam assures that the sustainer heater only turns on when the glasswasher is not in a cycle. This prevents the machine from drawing too much electrical current at any one time. Page PKD24B INSTALLATION & OPERATION MANUAL Rev. 11.09...
  • Page 6: Getting Started

    The supply water to the PKD24B must be a minimum of 140°F. The pipe supplying the water must be ½” minimum. The plumbing connection is located at the back of the machine. The drain is a 1"...
  • Page 7: Receiving And Installation

    2.2.3. Post Instructions Mount the wall chart provided in a conspicuous place and instruct the operators on proper cleaning and operation of the PKD24B. The instruction chart is also provided as an appendix to this manual (see appendix). Electrical and plumbing connections must be made by a qualified person who will comply with all...
  • Page 8: Installers Checklist

    Drain hose is installed with adequate air gap  Glasswasher is properly grounded  Glasswasher is properly leveled  Machine circuit breaker is labeled “Glasswasher”  Machine has been connected with correctly sized wire (12 gauge  minimum) Page PKD24B Installation & Operations Manual Rev. 11.09...
  • Page 9: Operation

    It is essential that the operator thoroughly understand the importance of pre-scrapping the dishes before loading them. The PKD24B is equipped with a removable drain screen. The drain screen can be easily removed for cleaning between Operational Cycles of the glasswasher.
  • Page 10: Proper Filling

    Cam 4 can be adjusted to increase the amount of water that is automatically fed into the machine during a cycle (see section 4.1.1 Cam Adjustment). Page PKD24B Installation & Operations Manual Rev. 11.09...
  • Page 11: Maintenance

    5. Adjust the trailing edge of the cam groove by rotating the appropriate side of the cam in the proper direction to either increase or decrease the cam’s groove; resulting in increasing or decreasing the total time that switch will be held ON. Page PKD24B PARTS MANUAL Rev. 1.15B...
  • Page 12: Quick Service Guide

    Replace solenoid coil, P/N 00738.10 NORMAL Delimer switch in wrong position Switch to position Sanitizer pump does not run Faulty 5th micro switch Replace switch, P/N 00411.00 Faulty sanitizer pump motor Replace motor, P/N 00416.00 Page PKD24B PARTS MANUAL Rev. 11.09...
  • Page 13: Troubleshooting

    Defective heater relay Replace heater relay P/N: 00631.00 *The timer assembly motor ( ) or micro switches ( ) can be replaced P/N: 00501.00 P/N: 00411.00 independently if that is the only component that has failed. Page PKD24B PARTS MANUAL Rev. 11.09...
  • Page 14 Replace timer assembly* (Cam 5) P/N: 00408.80 *The timer assembly motor ( ) or micro switches ( ) can be replaced P/N: 00501.00 P/N: 00411.00 independently if that is the only component that has failed. Page PKD24B PARTS MANUAL Rev. 11.09...
  • Page 15 Defective pump motor Replace pump motor P/N: 00201.00 *The timer assembly motor ( ) or micro switches ( ) can be replaced P/N: 00501.00 P/N: 00411.00 independently if that is the only component that has failed. Page PKD24B PARTS MANUAL Rev. 11.09...
  • Page 16: Addendum For Machines Installed In The City Of Chicago

    1. All low energy models must have low level sani-alarms, both visual and audio. 2. All models must have a City of Chicago approval data label affixed to the machine. 3. Chlorine sanitizer must be a minimum of 100 PPM. Page PKD24B PARTS MANUAL Rev. 1.15B...
  • Page 17: Appendix A: Operator & Cleaning Instructions

    Appendix A: Operator & Cleaning Instructions Page PKD24B PARTS MANUAL Rev. 1.15B...
  • Page 18 Electrical Diagram Page PKD24B PARTS MANUAL Rev. 11.09...
  • Page 19: Electrical Diagram (Effective 06/2007)

    Electrical Diagram 6. Electrical Diagram (Effective 06/2007) Page PKD24B PARTS MANUAL Rev. 11.09 Form No. Z2361...

Table of Contents