Serial Setup - Planet Networking & Communication ICS-2Serie User Manual

Industrial serial device server
Table of Contents

Advertisement

4.5.1 Serial setup

The serial setup screen is shown in
Object
• Description
• Baud Rate
• Stop Bits
• Data Bits
• Parity
• Interface
• Flow Control
User's Manual of ICS-2x00T Serial Device Server Series
Figure
4-5-2.
Figure 4-5-2: Serial Setup Page Screenshot
Description
Used to distinguish the name of each serial port. It allows 1 to 15 characters (e.g. A-Z,
a-z, 0-9)
The rate of data transmission to and from the attached serial device. It allows 50 bps to
921600 bps. The default is 921600 bps.
The stop bit follows the data and parity bits in serial communication. It indicates the end
of transmission. The default is 1.
Indicates the number of the bits in a transmitted data package. The allowed value is
5,6,7,8 and default value is 8.
This parameter controls the error checking mode. It support five modes and default
value is none.
Even
Odd
None
Space
Mark
The industrial device server supports three interfaces. The default value is RS-232.
RS-232
RS-422
RS-485 2-Wire
RS-485 4-Wire
The method is used to suspend and resume data transmission to ensure that data is not
lost. It supports four methods and default value is none.
None
RTS/CTS
Xon/Xoff
DTR/DSR
46