5 Installation

5.1 Electrical connection

The terminal indicated by
symbol
are normally earthed. Connect the
appliances appropriately using this
terminal in order to make sure that
they are equipotential.
If the phase voltage drops below
190V~, the performance of the
oven may suffer, not due to the
product itself.
General information
Check the grid characteristics against the
data indicated on the plate. The
identification plate bearing the technical
data, serial number and brand name is
visibly positioned on the appliance. Do not
remove this plate for any reason.
Perform the ground connection using a wire
that is 20 mm longer than the other wires.
50
Cleaning and maintenance
links up parts that
The appliance is provided with a five-core
H07RN-F cable (5 x 1.5 mm² referring to
the cross section of the internal conductor).
Connection modes:
• 220-240 V 1N~
3 x 4 mm² three-core cable.
• 380-415 V 2N~
4 x 2.5 mm² four-core cable.
• 380-415 V 3N~
5 x 1.5 mm² five-core cable.
The values indicated above refer
to the cross-section of the internal
conductor.