ABLE BEKA associates BA648CF-P Installation & Maintenance Instructions Manual

ABLE BEKA associates BA648CF-P Installation & Maintenance Instructions Manual

Panel mounting 8 variable fieldbus indicator profibus pa

Advertisement

Quick Links

Installation & Maintenance Instructions
BA648CF-P
Supplied by
.com
Call us on +44 (0)118 916 9420 | Email info@247able.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BEKA associates BA648CF-P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ABLE BEKA associates BA648CF-P

  • Page 1 Installation & Maintenance Instructions BA648CF-P Supplied by .com Call us on +44 (0)118 916 9420 | Email info@247able.com...
  • Page 2 Panel mounting 8 variable Fieldbus Indicator Reading Office Aberdeen Office Cutbush Park, Danehill, Lower Earley, Unit 6 Airside Business Park, Kirkhill Industrial Estate, Internet: www.able.co.uk Reading, Berkshire. RG6 4UT. UK. Dyce, Aberdeen. AB21 0GT. UK. e-procurement: www.247able.com Tel: +44 (0)118 9311188...
  • Page 3 BA648CF-P PROFIBUS PA Panel mounting 8 variable Fieldbus Indicator Issue: 2 Issue 2 June 2011...
  • Page 4: Table Of Contents

    CONTENTS 1. Description 6. Maintenance 1.1 Documentation 6.1 Fault finding during commissioning 6.2 Fault finding after commissioning 2.Operation 6.3 Servicing 2.1 Error messages 6.4 Routine maintenance 6.5 Guarantee 3. System Design for Hazardous Area 6.6 Customer comments 4. Installation 4.1 Location 7.
  • Page 5: Description

    1. DESCRIPTION 2. OPERATION The BA648CF-P fieldbus indicator is a general The BA648CF-P indicator can display up to eight purpose, PROFIBUS PA indicator that may be pre-configured PROFIBUS PA process variables configured as a fieldbus node or as a fieldbus designated in-1 to in-8.
  • Page 6: Installation

    4. INSTALLATION 4.2 Installation Procedure 4.1 Location a. Insert the BA648CF-P into the instrument The BA648CF-P is housed in a robust aluminium panel cut-out from the front of the panel. enclosure with a toughened glass window mounted in a Noryl bezel. The front of the instrument b.
  • Page 7: Configuration

    5. CONFIGURATION When set as required operating the P button will The BA648CF-P 8 variable PROFIBUS PA transfer control to the next digit that may be indicator may be configured as a fieldbus node or adjusted in the same way. When all digits are set as a fieldbus listener.
  • Page 8: Listener Configuration Menu

    Please refer to the quick set-up procedure in the 5.3 Listener configuration menu BEKA PROFIBUS PA Display – Fieldbus Interface When used as a fieldbus listener the BA648CF-P Guide. is not visible to the fieldbus host and can only be configured using the front panel push buttons 5.2.4 Reset the instrument to node factory shown in Fig 2.
  • Page 10: Access

    5.3.1 Access ‘SrC’ Enter Source Address Access to the listener configuration menu is Allows hexadecimal fieldbus obtained by operating the P and E buttons device source address for simultaneously. BA648CF-P listener each of the eight listener configuration menu is not protected by an access inputs in-1 to in-8 to be code the first parameter 'SCAn’...
  • Page 11: Description Of Listener Menu Functions

    5.4 Description of listener menu functions If the required process variable has an index This section contains a detailed description of each above 5 i.e. it is not the first five bytes in the data function in the listener configuration menu. string, the required index should be entered via the should be read in conjunction with Fig 6.
  • Page 12: Enter Source Address

    5.4.5 Enter source address ‘SrC’ 5.4.9 Configuration of bargraph display ‘bAr’ This function allows a known fieldbus device This function contains three sub-functions that source address to be entered and allocated to the enable the bargraph, justify its position and define listener input selected in the edit function.
  • Page 13: Configuration Menu

    The ‘SCALE’ function may be selected from within To change to a fieldbus node press the ▼ or ▲ the edit sub-menu by operating the ▼ or ▲ button. button which will toggle the display to ‘nodE’. To enter the function press P which will display the prevent accidental changes this request must be ‘GAin’...
  • Page 14: Maintenance

    6. MAINTENANCE 6.3 Servicing We recommend that faulty BA648CF-P Fieldbus 6.1 Fault finding during commissioning Indicators be returned to BEKA associates or to BA648CF-P fails function during our local agent for repair. commissioning the following procedure should be followed: 6.4 Routine maintenance The mechanical and electrical condition of the Symptom Cause...
  • Page 15: Accessories

    7. ACCESSORIES 7.1 Scale marking BA648CF-P indicators are fitted with a blank escutcheon around the liquid crystal display. specified when the instrument is ordered, this can be supplied printed with units of measurement and a scale for the horizontal bargraph. 7.2 Tag number The BA648CF-P can be supplied with a thermally printed tag number on the rear panel adjacent to...